If you want reliable HVAC and water heater services from an experienced contractor, you can count on Bluflame Service Co. Our technicians have the technology and expertise to give you the best possible service for these critical home systems. We offer quick and accurate repairs, maintenance, and installation of heating and cooling equipment, as well as the latest cutting-edge water heaters and indoor air quality systems.
Reach out to our team today to schedule an HVAC or water heater service. 
Air Conditioning Services
We provide comprehensive air conditioning services to keep you comfortable in the hottest weather. Our certified technicians can perform maintenance, repairs, and installation on many different models and brands. You can depend on us for:
- Installation and replacement: When the time comes for HVAC replacement, you can count on our professionals to recommend the best unit. Our installers will properly install it, checking all connections on the day and time you choose.
- Repair: Your cooling system will experience regular wear and tear. When that happens, our team is here to diagnose issues and walk you through various solutions.
- Maintenance: Preventive maintenance is an essential annual service that will help preserve the life of your air conditioning and prevent major breakdowns from occurring. With annual tune-ups, you won’t need HVAC replacement as often.
Heating Services
Without functional and effective heating, you cannot stay warm in winter. Bluflame Service provides heating services for furnaces, boilers, and heat pumps. We also offer zoning installation and temperature control to enhance indoor comfort further. Call us for heating services if you need:
- Installation and replacement: Our highly skilled professionals will properly size your home using critical factors to determine the best unit for your place. We will provide you with options that fit your home and budget.
- Repair: Nothing is worse than your heating system not functioning in the cold winters that the Maumee area experiences. Our technicians have the expertise and tools to diagnose and remedy the problem quickly.
- Maintenance: Annual maintenance is the best way to keep warm in winter and extend the lifespan of your heating unit. Schedule your tune-up in the fall before the weather turns frigid to catch potential issues.
Indoor Air Quality Services
Our services include more than heating and air conditioning. Indoor air quality plays a major role in your home’s comfort. Whether you want to install an air scrubber, air purifier, whole-home humidifier or dehumidifier, you can rely on our team to do the job. Our professionals can recommend indoor air quality services to improve home comfort and energy efficiency in your Maumee home.
Water Heater Services
Your water heater is an essential appliance in your home. If it’s outdated, it stops producing sufficient hot water, or you have skyrocketing water bills, it may be time for a replacement. We provide comprehensive water heater services, including installation for gas and electric water heaters and tankless water heaters.
Why Choose Bluflame Service?
Since 1954, we have provided comprehensive HVAC, indoor air quality, and water heater service to residents in Maumee. We offer upfront pricing, emergency service until 12 a.m., free service calls and replacement estimates, financing options, and special offers.
Schedule an appointment in Maumee with Bluflame Service Co. today!
Recent Jobs and Reviews in Maumee, OH
Job Locations and Reviews
Completed scheduled maintenance visit on 3-year-old air conditioning system as second appointment per customer request. Performed comprehensive inspection of indoor blower motor assembly and outdoor condenser unit, verifying proper operation of all electrical connections and mechanical components. Documented equipment condition with photos showing SUREPHON blower motor specifications and outdoor condenser unit with exposed service panel for maintenance records.
Completed annual furnace maintenance on an 8-year-old Lennox heating system. Performed comprehensive tune-up including combustion analysis, pressure testing, and system diagnostics using digital manometer. Inspected Aprilaire humidifier and associated plumbing connections. All equipment operating within normal parameters with no deficiencies noted.
Performed preventative maintenance tune-up on 6-year-old residential air conditioning system. Unit showed signs of environmental wear with dirty condenser coils, accumulated debris, and missing top protective grille exposing fan assembly. Cleaned condenser coils, removed debris from unit exterior, and documented compromised protective grille requiring future replacement to prevent weather damage and ensure safe operation.
Conducted comprehensive assessment of existing HVAC system for furnace replacement estimate. Evaluated current furnace unit, associated ductwork, PVC ventilation and drainage piping, and refrigerant line connections. Documented equipment specifications, manufacturer information, and system configuration including air handler cabinet and copper line routing. Photographed installation layout, mechanical connections, and surrounding utility space conditions to provide accurate replacement recommendations and ensure proper sizing for new equipment installation.
Completed preventive maintenance tune-up on 5-year-old residential air conditioning system. Inspected outdoor condensing unit and indoor air handler, verified proper operation of all components, checked electrical connections, and ensured system is operating within manufacturer specifications for the cooling season.
Completed full HVAC system installation in residential basement including 5-ton upflow cased coil, 96% efficiency 135,000 BTU upflow furnace with return-based configuration, and single-stage condenser unit. Installed new 7/8" x 50' refrigerant line set, condenser pad, disconnect and whip, 17-gallon humidifier, 5" filter rack, and WiFi-enabled thermostat for remote system control. Verified proper drainage with condensate trap installation, ensured level equipment placement, and confirmed all ductwork connections and electrical components were properly secured per manufacturer specifications.
Completed comprehensive tune-up service on 23-year-old HVAC system. Inspected condenser unit exterior components including coils, motor assembly, and refrigerant lines; noted significant accumulation of dirt and debris within unit housing requiring attention during future maintenance. Verified proper mounting and support of associated drainage lines and electrical conduit; all piping connections and wall supports found secure and functional.
Responded to no cooling call on Carrier HVAC system. Upon arrival, confirmed unit was completely non-operational with no power to air handler or condensing unit. Diagnosed electrical issue preventing system startup, restored power to equipment, and verified proper operation of all components before departure.
Responded to customer report of loud noise during furnace operation following recent installation. Upon inspection, discovered significant condensation accumulation on ductwork and air handler surfaces in attic space, indicating excessive moisture buildup due to inadequate insulation or air sealing. Documented moisture conditions on sheet metal ductwork and interior air handler components with photographic evidence. Identified condensation issue as likely source of reported operational noise. Advised customer of findings and recommended corrective measures to address humidity infiltration and prevent future condensation-related problems.
Completed full HVAC system installation in residential basement mechanical room. Installed upflow 96% efficiency two-stage furnace with return base and C-width upflow cased coil. Added 17-gallon whole-home humidifier with 5-inch filter rack for enhanced indoor air quality. Ran new 7/8-inch line set approximately 50 feet to exterior condensing unit. Installed 17 SEER two-stage air conditioning condenser, relocating unit 3 feet forward from electric meter for proper clearance and serviceability. Installed new electrical disconnect and whip for condensing unit per code requirements. Configured Wi-Fi enabled thermostat for remote system monitoring and control. All PVC intake and exhaust venting installed and secured to furnace. Copper refrigerant lines properly insulated and connected. System tested for proper operation including heating, cooling, and humidification functions. All components operating within manufacturer specifications.
Completed installation of a 40-gallon slim Bradford White residential water heater with proper copper piping connections, brass fittings, and galvanized venting system. Additionally installed a surge protector at the outdoor electrical disconnect on the exterior equipment, ensuring power was safely disconnected prior to installation.
Performed diagnostic assessment on residential air conditioning system. Upon arrival, communicated with customer that full system diagnosis would be required before proceeding with leak search and leak seal services. Connected refrigerant manifold gauges to measure system pressures, recording operating pressures and temperatures. Visual inspection revealed significant frost accumulation on refrigerant suction line, indicating potential restriction, low refrigerant charge, or metering device malfunction. Documented system conditions with photos showing pressure readings and frosted copper line with oxidation present. Deferred leak search procedure pending completion of comprehensive diagnostic evaluation to properly identify root cause of system malfunction.
Completed comprehensive estimate for full HVAC system replacement including both furnace and air conditioning units. Assessed existing basement-installed furnace with flexible duct connections and condensate drainage system, along with outdoor condensing unit mounted on concrete pad with electrical disconnect. Documented current equipment condition, measured installation space constraints, photographed existing components, and provided replacement recommendations for complete heating and cooling system upgrade.
Responded to service call for noisy blower motor on aging furnace system estimated at over 20 years old. Upon inspection, identified worn blower fan bearings as source of operational noise. Documented existing equipment condition with photos showing motor assembly with visible wear, paint deterioration, and flexible conduit connections, as well as internal cabinet components including ductwork and evaporator coil assembly. Customer advised of findings and equipment age considerations for future planning.
Completed comprehensive estimate for full HVAC system replacement including outdoor condensing unit and indoor Pulse brand furnace. Assessed existing equipment condition, documented current installation configuration with electrical service connections and PVC venting, and provided replacement specifications for both heating and cooling components to restore complete system functionality.
Responded to no cooling complaint on 47-year-old Lennox Pulse system with noise and drainage leak issues affecting entire home. Upon inspection, found unit had reached end of serviceable life with multiple component failures including compromised condensate drainage system causing water leakage at drain pipe. Documented existing equipment condition with photos showing aged furnace/HVAC unit in basement location with visible PVC venting and surrounding utility area. Advised customer that 1979-era Lennox Pulse system requires immediate replacement due to age, obsolete parts availability, and current system failures preventing proper operation and cooling capacity.
Completed maintenance tune-up on 4-year-old Goodman ground-level condenser unit. Performed standard preventative maintenance procedures including inspection of electrical components, capacitor testing, and system operational check. Customer reported home temperature reaching 80 degrees with insufficient airflow through supply and return vents; diagnostic assessment revealed undersized air conditioning system for square footage of residence. Pressure readings indicated 300 CFM at all supply vents except one register measuring 1700 CFM, suggesting possible ductwork restriction or damper imbalance. Inspected condenser coil, fan motor operation, and refrigerant lines during service visit. Accessed internal components through side panel to verify electrical connections and capacitor function. Recommended system evaluation for potential replacement due to inadequate cooling capacity for home size and airflow distribution issues requiring further investigation of duct system design and sizing
# HVAC Maintenance Service Completed
Performed comprehensive preventive maintenance on a 12+ year old air conditioning system. Conducted electrical diagnostics using digital multimeter to verify proper voltage and amperage readings across system components. Tested capacitor functionality and measured electrical values at 6.86 (volts/amps) to ensure operation within manufacturer specifications. Inspected all electrical connections, wire terminals, and control wiring for secure connections and proper configuration. Verified DiversiTech disconnect switch operation and exterior electrical panel integrity. System tested and confirmed operational following maintenance procedures.
Installed a 75-gallon Bradford White power vent water heater in the basement utility area. Connected all supply and discharge piping, including copper water lines and pressure relief valve, ensuring proper integration with the existing plumbing system. Mounted the power vent blower assembly to the unit and verified all connections for safe operation.
Responded to no hot water complaint at 48-year-old residence. Upon inspection, diagnosed failed tanked water heater requiring replacement. Removed old unit and installed new white cylindrical water heater in basement utility area. Connected copper supply lines with proper black foam pipe insulation to prevent heat loss and condensation. Installed recirculation pump with brass fittings at top of tank for improved hot water delivery throughout home. Verified all connections for leaks and proper operation. Used level to ensure tank installation meets manufacturer specifications for optimal performance and longevity. Tested system and confirmed hot water restoration to all fixtures.