Bluflame Service Co. has been Oregon, OH’s trusted HVAC partner since 1954. Proudly serving the local community, we’re dedicated to keeping your home comfortable with energy-efficient heating, cooling, and plumbing solutions. Whether you need emergency repairs, routine maintenance, or a new installation, you can count on our licensed and insured team to handle everything with expert care.
Don’t wait until your HVAC or plumbing needs become an emergency! Contact Bluflame Service for fast, reliable services.

Expert Air Conditioning Services
Our professional HVAC team and same-day services guarantee comfort and peace of mind during the hottest months. Whether you need a service for central air conditioners or ductless mini-split systems, our experts can ensure your comfort. Our air conditioning services include:
- Installation and replacement: Installing a new air conditioning system can make your home more energy-efficient, lower your utility bills, and give you better cooling, so you stay comfortable while saving money over time.
- Repair: If you notice weak airflow, odd noises, strange smells, or higher energy bills, these are signs your AC might need repair.
- Maintenance: The best time to schedule AC maintenance is in spring to ensure your system runs smoothly and avoid unexpected breakdowns.
Oregon Heating Services
When winter arrives and temperatures drop into the 20s, a dependable heating system is essential for staying warm. Bluflame Service offers expert heating services to ensure your furnace, boiler, or heat pump operates efficiently all season. Our heating services include:
- Installation and replacement: If your heating system is over 15 years old, constantly needs repairs, or isn’t heating your home efficiently, it might be time for a replacement to improve comfort and lower energy costs.
- Repair: Addressing heating issues early can prevent bigger problems in the future and save you from costly repairs or a complete system failure.
- Maintenance: Our comprehensive maintenance checks ensure your heating system runs efficiently, catch potential issues early, and extend the lifespan of your equipment.
Indoor Air Quality Services in Oregon
At Bluflame Service, we understand clean, healthy indoor air is essential for your comfort and well-being. Our indoor air quality services include:
- Air scrubbers: Our advanced air scrubbers work to eliminate airborne contaminants, including bacteria, viruses, and allergens, ensuring the air you breathe is as clean and fresh as possible.
- Air purifiers: We offer high-performance air purifiers designed to capture and eliminate particles such as dust, pollen, pet dander, and mold spores, helping to create a healthier indoor environment.
- Whole-home humidifiers and dehumidifiers: Whether you need to add moisture to dry winter air or reduce humidity in the summer, our whole-home humidifiers and dehumidifiers maintain optimal moisture levels, preventing issues like dry skin, allergies, and mold growth.
Reliable Water Heater Services
Our experienced team provides comprehensive solutions for all types of water heaters, including traditional, gas, electric, and tankless models. Our water heater services include:
- Installation and replacement: Whether upgrading to a more energy-efficient system or replacing an outdated unit, we help you choose the right model for your home’s needs.
- Repair: If your water heater is making strange noises, leaking, or failing to heat water properly, our team is ready to diagnose and repair the issue quickly.
- Maintenance: We offer thorough inspections, flushing, and component checks to keep your system running reliably year-round.
Why Choose Bluflame Service for HVAC and Plumbing Services?
Bluflame Service Co. provides Oregon, OH, residents with HVAC and plumbing systems to ensure your home’s comfort. Take advantage of free replacement estimates and upfront pricing. Our background-checked technicians deliver trustworthy, high-quality service, and with financing options available, we ensure comfort fits your budget. Plus, we offer special discounts for military, veterans, and seniors.
Experience top-notch HVAC and plumbing service in Oregon, OH. Contact us to schedule services today!
Bluflame Service Company has completed 20 jobs in Oregon, OH between October 2026 and November 2026. The most recent job was on November 4, 2026. Bluflame Service Company has completed 133 jobs in Oregon, OH in the last 12 months.Recent Jobs and Reviews in Oregon, OH
Oregon, OH at a glance
Job Locations and Reviews
Performed annual maintenance on a 23-year-old natural gas furnace, including a combustion analysis to verify safe and efficient operation. Readings showed CO at 5 ppm (air-free 9 ppm), O₂ at 9.3%, CO₂ at 6.56%, stack temperature of 116°F, and 90% combustion efficiency, with manifold gas pressure measured at 3.52 inH₂O, all within acceptable operating parameters.
Responded to a no-heat call on a 4-year-old furnace and inspected the unit, finding heavy lint and dust buildup around the gas supply line penetration and control components, along with surface corrosion on the cabinet. Cleaned the debris from the affected areas, checked the gas supply connections and electrical components, and restored heating operation. Furnace is now cycling and producing heat normally.
Performed an on-site evaluation for replacement of an existing WhisperHeat upright gas furnace and associated components, including a Space-Gard electronic air cleaner, a duct-mounted humidifier with supply piping, galvanized plenum with foil-faced insulation, and flue venting with elbow transition. Documented the equipment's overall condition, which is typical of an aging installation with light dust accumulation and no evident rust, frost, or major damage, and assessed the existing ductwork, venting, and accessory connections for compatibility with a new high-efficiency system and proper sizing.
Performed scheduled heating maintenance on a 2-year-old Lennox natural gas furnace, including a visual inspection of the equipment, venting, ductwork, and electrical connections with no damage, rust, or leaks observed. Conducted a combustion analysis with a Testo 310 flue gas analyzer, recording a stack temperature of 96.2°F, 7.0% O2, 7.86% CO2, 21 ppm CO (32 ppm air-free), and 95.7% efficiency, confirming the furnace is operating safely and within normal parameters.
Performed annual maintenance on an 8-year-old gas furnace, including removal of the access panel and vacuum cleaning of the burner compartment and cabinet interior to clear dust and debris. Inspected internal components, including the control board wiring, condensate drain hose and clamps, and the cabinet floor, and noted heavy rust and corrosion on the access panel and rust staining at the base of the cabinet, which should be monitored for moisture intrusion. Reinstalled the access panel and verified proper unit operation.
Performed annual maintenance on a gas-fired furnace, including inspection of the blower assembly, wiring, and cabinet interior, and verified the 16x20x4 air filter installation and airflow orientation. Conducted combustion analysis with a flue gas analyzer and digital manometer, recording CO at 7 ppm, 90.8% efficiency, 11.4% O2, 107.6°F stack temperature, and 3.50 inH2O differential pressure. Noted debris in the bottom of the cabinet and moisture spotting on the interior panel for monitoring.
Performed annual heating maintenance on a 22-year-old gas furnace, including a combustion analysis with a Testo 310 II and 510i manometer. Initial readings showed stack temperature of 107.6°F, CO at 7 ppm, O₂ at 11.4%, and gas manifold pressure of 3.50 inH₂O; after service, readings stabilized at stack temperature of 279.8°F, CO at 11 ppm, O₂ at 10.7%, and manifold pressure of 1.74 inH₂O with steady-state efficiency of 82.2%. CO levels remained within acceptable limits and the furnace is operating safely.
Performed annual heating maintenance on a 19-year-old garage-installed gas furnace, including inspection of the burner assembly, gas manifold, and gas valve. Verified manifold gas pressure at 3.44 in. w.c. with a digital manometer, within normal operating range for natural gas. Observed light dust accumulation on the gas valve and cabinet interior with no evidence of rust, frost, or component damage.
Installed a new 80% AFUE, 70,000 BTU Merit Series A-cabinet gas furnace in a confined closet, leveling the unit and connecting the flue vent to the existing ductwork. Completed rigid metal gas piping and electrical connections, routed the condensate/drain line, and installed a new thermostat to complete the system replacement.
Performed a courtesy inspection on an older Rheem gas furnace, including a combustion analysis with a Testo 310 flue gas analyzer, which showed natural gas readings of 116.7°F stack temperature, 11.3% O2, 5.44% CO2, 12 ppm CO (26 ppm air-free), 104.3% excess air, and 88.1% combustion efficiency. Evaluated general equipment operation and condition, including the inducer assembly and PVC venting, to help determine whether repair or replacement is the better option.
Conducted a furnace replacement estimate, inspecting the existing belt-driven blower furnace and noting heavy dust and debris accumulation, discoloration and staining on the galvanized flue, and loose wiring near the PVC condensate/vent piping, all indicating an aged unit in need of replacement. Also assessed the exterior equipment, including the gas meter, condenser unit, insulated refrigerant line set, and electrical disconnect, finding no visible frost, rust, or damage, and documented all conditions with photos to support replacement recommendations.
Responded to a no-heat call on a 15–20 year old gas furnace and inspected the unit, finding heavy soot, dirt, and corrosion buildup in the burner and control compartment along with aged, taped wiring in need of attention. Performed a borescope inspection of the heat exchanger, which showed weld seam discoloration and rust streaking near fine cracks and openings, indicating age-related deterioration that warrants continued monitoring and evaluation for replacement.
Performed annual heating maintenance on a 7-year-old gas furnace, including combustion analysis with a flue gas analyzer and manometer. Readings showed CO of 46 ppm, CO₂ at 6.39%, O₂ at 9.6%, stack temperature of 360°F, net efficiency of 80.2%, and manifold differential pressure of 3.49 inH₂O on natural gas, confirming safe, stable operation within acceptable parameters.
Performed a seasonal heating tune-up on a 5-year-old gas furnace, inspecting the cabinet, gas piping connections, PVC venting, and condensate drain system. Verified the condensate pump and drain line were properly connected and functioning, and noted corrosion on nearby brass fittings and dust accumulation in the mechanical space for the homeowner's awareness. Gas piping joints and unions showed no evidence of leaks, and the system was left operating normally.
Performed seasonal heating maintenance on a 3-year-old Lennox gas furnace, including inspection of the burner assembly, heat exchanger, condensate drain, flue/venting, and ductwork connections, with operation verified through a full heating cycle. Inspected the 14x20x1 return filter and the Aprilaire whole-home humidifier and control, and confirmed no visible leaks, corrosion, or damage. System was left operating normally.
Performed a seasonal tune-up on the gas furnace located in the attic. Inspected the system and replaced the heavily soiled pleated air filter, which was clogged with dust and debris, to restore proper airflow and improve system efficiency.
Performed a seasonal tune-up on a 2-year-old gas furnace, inspecting the cabinet interior, condensate drain line, and electrical connections. Found significant rust and corrosion on the galvanized cabinet floor beneath the condensate drain hose and fitting, indicating a possible past or ongoing leak at the drain connection; recommend monitoring and further evaluation. Condensate PVC drain piping and rubber coupling were secure and free of cracking or damage, and the 16x25x1 air filter was verified in place.
Performed annual maintenance on a 12-year-old gas furnace, including a combustion analysis that measured 7.1% O₂, 7.80% CO₂, 21 ppm CO (32 ppm air-free), 108.8°F stack temperature, and 93.5% efficiency, with 3.48 inH₂O differential pressure recorded. Identified heavy rust and corrosion on the cabinet floor, indicating prolonged moisture exposure or leakage, and recommend further inspection of the condensate and venting components to determine the source.
Returned to property to replace malfunctioning thermostat with new Honeywell Home digital programmable unit from truck stock. Removed old thermostat, connected wiring to appropriate terminals on new unit, mounted device to wall, and verified proper system operation with successful temperature display and control functionality.
Completed comprehensive maintenance on a 20-year-old gas heating system under the MVP Heat maintenance plan. Performed combustion analysis using calibrated testing equipment, confirming proper operation with stack temperature of 115.4°F, oxygen level at 8.5%, carbon monoxide at 5 ppm, and system efficiency at 90.4%. All measurements fall within acceptable parameters for safe and efficient operation.