Emergency Service Hours Until 12:00 AM
At Bluflame, our commitment to your comfort extends beyond regular hours. Our service ensures that whenever heating or cooling issues arise, our dedicated team is ready to address them promptly. Our skilled technicians are just a call away; call us at (419) 379-3527 to schedule a service.

Your Trusted HVAC Experts In Toledo, OH

From older brick homes near Old Orchard and Ottawa Hills to neighborhoods surrounding Alexis Road, Airport Highway, and Point Place, Toledo homeowners deal with heating, cooling, and plumbing problems tied directly to the age of their homes. Bluflame Service receives calls throughout Toledo every day for furnace breakdowns, sump pump failures, aging boilers, leaking water heaters, airflow issues, and older AC systems struggling through Northwest Ohio humidity. Many Toledo homes still operate with older ductwork, aging plumbing lines, and HVAC equipment that has been repaired multiple times over the years.

Whether your furnace stopped working during a cold snap off Lake Erie or your basement sump pump cannot keep up during heavy rain, Bluflame Service is ready to help. Call (419) 379-3527 or contact us online to schedule service anywhere in Toledo.

HVAC, Plumbing & Comfort Problems In Toledo, OH Homes

No two Toledo neighborhoods seem to have the exact same setup when it comes to heating, cooling, and plumbing systems. Homes near the University of Toledo often have older radiators and boiler systems, while neighborhoods farther west near Holland-Sylvania Road and Secor Road may have newer additions, remodeled lower levels, or mixed HVAC systems added over time. We regularly work in homes where part of the system is modern while another portion of the house is still relying on older ductwork or plumbing infrastructure.

That combination creates a lot of the frustrating problems homeowners start noticing over time. Some rooms heat unevenly, upper floors stay warmer during summer, older drains begin slowing down, and equipment starts running longer than it used to. Our technicians already work throughout Toledo every week and understand the common issues tied to the city’s older housing stock and changing weather patterns.

Air Conditioning & Cooling Services In Toledo, OH

Toledo summers can put a lot of strain on older cooling systems, especially once humidity builds across Lucas County. We spend a lot of time helping homeowners whose cooling systems never seem to fully catch up once the hotter, humid stretches of summer settle in. Cooling services available throughout Toledo include:

Homes near Glendale Avenue, Douglas Road, and the older neighborhoods surrounding Central Avenue often have duct systems that were never designed for modern cooling demands. A lot of Toledo homes have airflow bottlenecks hidden inside older duct systems. Sometimes the biggest improvement comes from correcting how the system moves air through the house instead of replacing everything outright.

Plumbing & Water Heater Services In Toledo, OH

Most plumbing problems we see in Toledo are issues that slowly became harder to ignore. Slow drains, inconsistent hot water, basement moisture, dripping faucets, and noisy sump pumps are common issues throughout the city. Bluflame provides:

A lot of Toledo homes still have aging plumbing infrastructure that has been repaired repeatedly over the years. During winter, frozen pipes and failing sump pumps become especially common in older homes with partially finished basements or crawl spaces. We also see hard water buildup affecting water heaters and fixtures throughout many areas of Toledo, particularly in homes where the equipment has not been flushed or maintained regularly.

Heating & Boiler Services In Toledo, OH

Heating systems in Toledo homes vary dramatically depending on when the house was built. Some homes still rely on boiler heat and radiators, while others have gone through multiple furnace upgrades over the decades. It is common for us to walk into homes where additions were added years later and the heating system was never fully adjusted to handle the extra square footage. Heating services throughout Toledo include:

During Toledo cold snaps, we regularly see heating systems that technically still operate but cannot hold temperature once the lake-effect wind and freezing air move through the area. In many cases, the issue involves restricted airflow, aging blower motors, dirty ductwork, or boilers that are losing efficiency after years of heavy use.

Indoor Air Quality & Duct Repair In Toledo, OH

Many homeowners are surprised to find out their comfort issues are tied more to airflow than the actual temperature setting on the thermostat. Older homes throughout neighborhoods near Bancroft Street, Jackman Road, and Reynolds Road often develop duct leaks, uneven airflow, and dust buildup that affect comfort year-round. Bluflame offers:

Many homeowners notice certain rooms feeling stuffy while other areas become overly dry during winter heating season. Proper duct repairs and indoor air quality upgrades can help reduce dust circulation, improve airflow consistency, and make heating and cooling systems work more efficiently throughout the home.

Why Toledo Homeowners Choose Bluflame Service

Most homeowners calling us are looking for straightforward answers and repairs that actually solve the problem instead of turning into a sales presentation. Because Toledo is one of the core areas we serve every day, our team is able to respond quickly throughout the city when heating, cooling, or plumbing problems cannot wait. Homeowners throughout Toledo continue choosing Bluflame because we provide:

  • Fast scheduling and responsive service
  • Emergency repair availability
  • Experienced HVAC and plumbing technicians
  • Clear communication from start to finish
  • Financing options on qualifying systems
  • Honest recommendations without pressure

We know most people are trying to make smart repair decisions without feeling rushed into replacing equipment before it is truly necessary. We take time to explain what we found, what can be repaired, and when replacement may actually make more financial sense long term.

Reviews From Toledo Area Homeowners

“Mike from Blue Flame came through for me to find a part for a blower motor for my furnace today. Great phone service and when I got into the store, great personal service. He answered all the questions that I needed.”

Jeff H. (Homeowner, Toledo Resident) – Rated 5/5 Stars

“I called to place a service call and was promptly scheduled within 2 hours. Jeff Cousino was absolutely amazing. He had the furnace up and running shortly after arriving. He was friendly, efficient, professional and explained everything.”

Matt W. (Homeowner, Toledo Resident) – Rated 5/5 Stars

“We purchased the new HVAC system from Blue Flame a couple of years ago. As part of the contract we had a free maintenance call today. Jeff Cousino seemed very capable and was very friendly. I have great confidence in the Blue Flame company.”

Mindy R. (Homeowner, Toledo Resident) – Rated 5/5 Stars

Schedule HVAC Or Plumbing Service In Toledo, OH

Whether you are dealing with an aging boiler near the Old West End, uneven cooling in a remodeled Toledo home, or a sump pump that cannot keep up during heavy rain, Bluflame Service is ready to help. Our technicians already work throughout Toledo every week and understand the real problems homeowners here deal with during every season.

Call (419) 379-3527 or contact Bluflame Service online today to schedule heating, cooling, plumbing, or indoor air quality service in Toledo, OH.

Recent Jobs and Reviews in Toledo, OH

Toledo, OH at a glance

Bluflame Service Company has completed 20 jobs in Toledo, OH in October 2026.

The most recent job was on October 16, 2026.

Bluflame Service Company has completed 1,771 jobs in Toledo, OH in the last 12 months.

Job Locations and Reviews

Performed annual maintenance on a 9-year-old gas furnace, including combustion analysis using a testo 310 II analyzer and testo 510i differential pressure probe. Final readings showed 5.49% CO₂, 11.2% O₂, 9 ppm CO, 84.5% combustion efficiency, 230.9°F stack temperature, and 3.48 inH₂O differential pressure, an improvement from initial readings of 3.46% CO₂, 14.8% O₂, 18 ppm CO, 83.3% efficiency, and 1.77 inH₂O. Results indicate the furnace is operating within normal combustion parameters.
Performed annual maintenance on a 9-year-old gas furnace, including combustion analysis using a testo 310 II analyzer and testo 510i differential pressure probe. Final readings showed 5.49% CO₂, 11.2% O₂, 9 ppm CO, 84.5% combustion efficiency, 230.9°F stack temperature, and 3.48 inH₂O differential pressure, an improvement from initial readings of 3.46% CO₂, 14.8% O₂, 18 ppm CO, 83.3% efficiency, and 1.77 inH₂O. Results indicate the furnace is operating within normal combustion parameters.
Dan T.
Dan T. Checked in
Performed annual maintenance on a 9-year-old gas furnace, including combustion analysis using a testo 310 II analyzer and testo 510i differential pressure probe. Final readings showed 5.49% CO₂, 11.2% O₂, 9 ppm CO, 84.5% combustion efficiency, 230.9°F stack temperature, and 3.48 inH₂O differential pressure, an improvement from initial readings of 3.46% CO₂, 14.8% O₂, 18 ppm CO, 83.3% efficiency, and 1.77 inH₂O. Results indicate the furnace is operating within normal combustion parameters.
Toledo, OH 43605
Performed a seasonal tune-up on a 6-year-old Amana natural gas furnace, inspecting the flue, condensate drain, refrigerant line, and plenum connections for leaks, corrosion, and proper support. Conducted a combustion analysis with a Testo 310 II, recording a stack temperature of 358.6°F, 9.2% O₂, 6.62% CO₂, 16 ppm CO (29 ppm air-free), and 80.3% efficiency, with all readings within acceptable limits for safe operation. System is operating normally with no visible frost, ice, or rust.
Performed a seasonal tune-up on a 6-year-old Amana natural gas furnace, inspecting the flue, condensate drain, refrigerant line, and plenum connections for leaks, corrosion, and proper support. Conducted a combustion analysis with a Testo 310 II, recording a stack temperature of 358.6°F, 9.2% O₂, 6.62% CO₂, 16 ppm CO (29 ppm air-free), and 80.3% efficiency, with all readings within acceptable limits for safe operation. System is operating normally with no visible frost, ice, or rust.
Jeff C.
Jeff C. Checked in
Performed a seasonal tune-up on a 6-year-old Amana natural gas furnace, inspecting the flue, condensate drain, refrigerant line, and plenum connections for leaks, corrosion, and proper support. Conducted a combustion analysis with a Testo 310 II, recording a stack temperature of 358.6°F, 9.2% O₂, 6.62% CO₂, 16 ppm CO (29 ppm air-free), and 80.3% efficiency, with all readings within acceptable limits for safe operation. System is operating normally with no visible frost, ice, or rust.
Toledo, OH 43613
Performed a heating tune-up on the gas furnace, including a combustion analysis with a calibrated flue gas analyzer that showed 108.5°F stack temperature, 6.6% O₂, 8.08% CO₂, 16 ppm CO (23 ppm air-free), 41% excess air, and 93.6% combustion efficiency. All readings were within normal operating parameters for natural gas, and the system was left operating properly.
Performed a heating tune-up on the gas furnace, including a combustion analysis with a calibrated flue gas analyzer that showed 108.5°F stack temperature, 6.6% O₂, 8.08% CO₂, 16 ppm CO (23 ppm air-free), 41% excess air, and 93.6% combustion efficiency. All readings were within normal operating parameters for natural gas, and the system was left operating properly.
Jeff C.
Jeff C. Checked in
Performed a heating tune-up on the gas furnace, including a combustion analysis with a calibrated flue gas analyzer that showed 108.5°F stack temperature, 6.6% O₂, 8.08% CO₂, 16 ppm CO (23 ppm air-free), 41% excess air, and 93.6% combustion efficiency. All readings were within normal operating parameters for natural gas, and the system was left operating properly.
Toledo, OH 43613
Toledo, OH - Performed on-site evaluation and estimate for replacement of an existing upflow gas furnace in the basement utility area, documenting the unit's cabinet, flue vent, supply plenum, and ductwork connections for replacement scoping. Inspected the electrical disconnect and flexible conduit serving the equipment, and noted the existing flue and duct configuration to be accounted for in the installation of the new unit.
Gabe S.
Gabe S. Checked in
Performed on-site evaluation and estimate for replacement of an existing upflow gas furnace in the basement utility area, documenting the unit's cabinet, flue vent, supply plenum, and ductwork connections for replacement scoping. Inspected the electrical disconnect and flexible conduit serving the equipment, and noted the existing flue and duct configuration to be accounted for in the installation of the new unit.
Toledo, OH 43607
Responded to complaint of furnace short cycling and reduced heating efficiency; inspected the Armstrong Air gas furnace and observed the burner assembly firing with a stable blue flame across all burners. Evaluated the venting and combustion components, including the galvanized flue connection to the water heater vent, as part of the short-cycling diagnosis, and noted dirty burner compartment with debris and residue. Furnace was left operating and cycling through the heat call.
Responded to complaint of furnace short cycling and reduced heating efficiency; inspected the Armstrong Air gas furnace and observed the burner assembly firing with a stable blue flame across all burners. Evaluated the venting and combustion components, including the galvanized flue connection to the water heater vent, as part of the short-cycling diagnosis, and noted dirty burner compartment with debris and residue. Furnace was left operating and cycling through the heat call.
Jeff C.
Jeff C. Checked in
Responded to complaint of furnace short cycling and reduced heating efficiency; inspected the Armstrong Air gas furnace and observed the burner assembly firing with a stable blue flame across all burners. Evaluated the venting and combustion components, including the galvanized flue connection to the water heater vent, as part of the short-cycling diagnosis, and noted dirty burner compartment with debris and residue. Furnace was left operating and cycling through the heat call.
Toledo, OH 43605
Performed annual maintenance on a 14-year-old gas furnace, including a combustion analysis with a testo 310 II that confirmed safe operation at 96.5% efficiency, 53 ppm CO, 7.24% CO2, 8.1% O2, and 93.5°F stack temperature. Inspected the furnace and associated ductwork, including the bypass-style humidifier and its water supply and drain connections, and verified proper system operation at completion.
Performed annual maintenance on a 14-year-old gas furnace, including a combustion analysis with a testo 310 II that confirmed safe operation at 96.5% efficiency, 53 ppm CO, 7.24% CO2, 8.1% O2, and 93.5°F stack temperature. Inspected the furnace and associated ductwork, including the bypass-style humidifier and its water supply and drain connections, and verified proper system operation at completion.
Dan T.
Dan T. Checked in
Performed annual maintenance on a 14-year-old gas furnace, including a combustion analysis with a testo 310 II that confirmed safe operation at 96.5% efficiency, 53 ppm CO, 7.24% CO2, 8.1% O2, and 93.5°F stack temperature. Inspected the furnace and associated ductwork, including the bypass-style humidifier and its water supply and drain connections, and verified proper system operation at completion.
Toledo, OH 43613
Performed an on-site evaluation of the existing gas furnace and air handler for full system replacement, inspecting the control board, wiring harness, blower assembly, burner section, igniter, pressure switch, and condensate drain components. Documented heavy dust and debris accumulation, loose insulation near the motor, taped wiring repairs, and a 10x20x1 return filter, with photos taken to support the replacement recommendation for both the furnace and AC.
Performed an on-site evaluation of the existing gas furnace and air handler for full system replacement, inspecting the control board, wiring harness, blower assembly, burner section, igniter, pressure switch, and condensate drain components. Documented heavy dust and debris accumulation, loose insulation near the motor, taped wiring repairs, and a 10x20x1 return filter, with photos taken to support the replacement recommendation for both the furnace and AC.
Gabe S.
Gabe S. Checked in
Performed an on-site evaluation of the existing gas furnace and air handler for full system replacement, inspecting the control board, wiring harness, blower assembly, burner section, igniter, pressure switch, and condensate drain components. Documented heavy dust and debris accumulation, loose insulation near the motor, taped wiring repairs, and a 10x20x1 return filter, with photos taken to support the replacement recommendation for both the furnace and AC.
Toledo, OH 43623
Responded to a reported gas leak with gas service shut off and leak source unknown, and inspected the gas piping at the water heater, including the black iron supply line, ball valve, and flexible appliance connectors, along with accessible gas piping in the basement floor joist area. Leak location was not identified on the initial visit, so a follow-up appointment is required to return and complete an air pressure test of the gas piping system to isolate the leak before restoring service.
Responded to a reported gas leak with gas service shut off and leak source unknown, and inspected the gas piping at the water heater, including the black iron supply line, ball valve, and flexible appliance connectors, along with accessible gas piping in the basement floor joist area. Leak location was not identified on the initial visit, so a follow-up appointment is required to return and complete an air pressure test of the gas piping system to isolate the leak before restoring service.
Virgil G.
Virgil G. Checked in
Responded to a reported gas leak with gas service shut off and leak source unknown, and inspected the gas piping at the water heater, including the black iron supply line, ball valve, and flexible appliance connectors, along with accessible gas piping in the basement floor joist area. Leak location was not identified on the initial visit, so a follow-up appointment is required to return and complete an air pressure test of the gas piping system to isolate the leak before restoring service.
Toledo, OH 43606
Performed an on-site replacement estimate for an existing downflow Goodman gas furnace installed in a closet, with a possible add-on or replacement of the air conditioning system. Inspected the cabinet, PVC condensate drain assembly with trap, flexible electrical conduit, and return-air filter section, noting debris in the condensate drain area and documenting existing conditions with photographs to determine equipment sizing and replacement scope.
Performed an on-site replacement estimate for an existing downflow Goodman gas furnace installed in a closet, with a possible add-on or replacement of the air conditioning system. Inspected the cabinet, PVC condensate drain assembly with trap, flexible electrical conduit, and return-air filter section, noting debris in the condensate drain area and documenting existing conditions with photographs to determine equipment sizing and replacement scope.
Gabe S.
Gabe S. Checked in
Performed an on-site replacement estimate for an existing downflow Goodman gas furnace installed in a closet, with a possible add-on or replacement of the air conditioning system. Inspected the cabinet, PVC condensate drain assembly with trap, flexible electrical conduit, and return-air filter section, noting debris in the condensate drain area and documenting existing conditions with photographs to determine equipment sizing and replacement scope.
Toledo, OH 43613
Performed annual tune-up on basement gas furnace (approx. 1.5 years old), including combustion analysis on natural gas with a Testo 310 II analyzer and static/differential pressure check. Initial readings showed stable operation at 87.8% efficiency, 7.6% O2, 42 ppm CO, and 143.6°F stack temp; later readings reflected steady-state operation at 80.2% efficiency, 7.1% O2, and 71 ppm CO with 3.45 inH2O differential pressure. Unit operating properly with no issues found.
Performed annual tune-up on basement gas furnace (approx. 1.5 years old), including combustion analysis on natural gas with a Testo 310 II analyzer and static/differential pressure check. Initial readings showed stable operation at 87.8% efficiency, 7.6% O2, 42 ppm CO, and 143.6°F stack temp; later readings reflected steady-state operation at 80.2% efficiency, 7.1% O2, and 71 ppm CO with 3.45 inH2O differential pressure. Unit operating properly with no issues found.
Dan T.
Dan T. Checked in
Performed annual tune-up on basement gas furnace (approx. 1.5 years old), including combustion analysis on natural gas with a Testo 310 II analyzer and static/differential pressure check. Initial readings showed stable operation at 87.8% efficiency, 7.6% O2, 42 ppm CO, and 143.6°F stack temp; later readings reflected steady-state operation at 80.2% efficiency, 7.1% O2, and 71 ppm CO with 3.45 inH2O differential pressure. Unit operating properly with no issues found.
Toledo, OH 43623
Performed an on-site evaluation for replacement of an existing Moncrief upright gas furnace located in an unfinished basement utility space. Inspected the furnace cabinet, supply plenum, galvanized ductwork, and flexible duct connections, documenting equipment condition and installation clearances with photographs. Existing unit shows age-related dust accumulation with no visible frost or major corrosion, and the documented findings were used to determine replacement scope and sizing.
Performed an on-site evaluation for replacement of an existing Moncrief upright gas furnace located in an unfinished basement utility space. Inspected the furnace cabinet, supply plenum, galvanized ductwork, and flexible duct connections, documenting equipment condition and installation clearances with photographs. Existing unit shows age-related dust accumulation with no visible frost or major corrosion, and the documented findings were used to determine replacement scope and sizing.
Gabe S.
Gabe S. Checked in
Performed an on-site evaluation for replacement of an existing Moncrief upright gas furnace located in an unfinished basement utility space. Inspected the furnace cabinet, supply plenum, galvanized ductwork, and flexible duct connections, documenting equipment condition and installation clearances with photographs. Existing unit shows age-related dust accumulation with no visible frost or major corrosion, and the documented findings were used to determine replacement scope and sizing.
Toledo, OH 43609
Toledo, OH - Performed seasonal heating maintenance on a 7-year-old basement-installed natural gas furnace, including a combustion analysis with a stack temperature of 108°F, 94.4% efficiency, 6.1% O₂, 8.36% CO₂, and 42 ppm CO, with a measured differential pressure of 3.48 inH₂O. System was operated and tested to verify safe, proper heating performance.
Dan T.
Dan T. Checked in
Performed seasonal heating maintenance on a 7-year-old basement-installed natural gas furnace, including a combustion analysis with a stack temperature of 108°F, 94.4% efficiency, 6.1% O₂, 8.36% CO₂, and 42 ppm CO, with a measured differential pressure of 3.48 inH₂O. System was operated and tested to verify safe, proper heating performance.
Toledo, OH 43606
Installed a new complete split system consisting of a 96% AFUE, 90,000 BTU downflow gas furnace with matching cased evaporator coil, metal-supply plenum transition, and a 12-gallon humidifier, with PVC intake/exhaust venting and condensate drain piping routed and secured. Set a new single-stage air conditioning condenser on a new concrete pad and connected it with a new 3/4" x 50' insulated refrigerant lineset, a new electrical disconnect, and a flexible conduit whip. Installed a Wi-Fi thermostat to complete the system controls.
Installed a new complete split system consisting of a 96% AFUE, 90,000 BTU downflow gas furnace with matching cased evaporator coil, metal-supply plenum transition, and a 12-gallon humidifier, with PVC intake/exhaust venting and condensate drain piping routed and secured. Set a new single-stage air conditioning condenser on a new concrete pad and connected it with a new 3/4" x 50' insulated refrigerant lineset, a new electrical disconnect, and a flexible conduit whip. Installed a Wi-Fi thermostat to complete the system controls.
Aaron T.
Aaron T. Checked in
Installed a new complete split system consisting of a 96% AFUE, 90,000 BTU downflow gas furnace with matching cased evaporator coil, metal-supply plenum transition, and a 12-gallon humidifier, with PVC intake/exhaust venting and condensate drain piping routed and secured. Set a new single-stage air conditioning condenser on a new concrete pad and connected it with a new 3/4" x 50' insulated refrigerant lineset, a new electrical disconnect, and a flexible conduit whip. Installed a Wi-Fi thermostat to complete the system controls.
Toledo, OH 43615
Performed scheduled heating tune-up on a 10-year-old gas furnace under the maintenance agreement, inspecting the burner assembly, wiring harness, control board, transformer, and cabinet interior. Documented heavy rust and corrosion on the burner compartment shelf, the vertical cabinet panel, and the cabinet floor beneath the transformer and wiring, indicating prolonged moisture exposure or leakage. Recommend further evaluation of the moisture source and corroded components to prevent premature failure.
Performed scheduled heating tune-up on a 10-year-old gas furnace under the maintenance agreement, inspecting the burner assembly, wiring harness, control board, transformer, and cabinet interior. Documented heavy rust and corrosion on the burner compartment shelf, the vertical cabinet panel, and the cabinet floor beneath the transformer and wiring, indicating prolonged moisture exposure or leakage. Recommend further evaluation of the moisture source and corroded components to prevent premature failure.
Levi S.
Levi S. Checked in
Performed scheduled heating tune-up on a 10-year-old gas furnace under the maintenance agreement, inspecting the burner assembly, wiring harness, control board, transformer, and cabinet interior. Documented heavy rust and corrosion on the burner compartment shelf, the vertical cabinet panel, and the cabinet floor beneath the transformer and wiring, indicating prolonged moisture exposure or leakage. Recommend further evaluation of the moisture source and corroded components to prevent premature failure.
Toledo, OH 43613
Performed annual heating maintenance on a 5-year-old gas furnace, including a combustion analysis with a digital analyzer under steady-state operation. Final readings showed 94.8% efficiency, 28 ppm CO, 8.31% CO₂, 6.2% O₂, a 104.6°F stack temperature, and 3.48 inH₂O manifold differential pressure, indicating safe, efficient combustion within normal operating parameters.
Performed annual heating maintenance on a 5-year-old gas furnace, including a combustion analysis with a digital analyzer under steady-state operation. Final readings showed 94.8% efficiency, 28 ppm CO, 8.31% CO₂, 6.2% O₂, a 104.6°F stack temperature, and 3.48 inH₂O manifold differential pressure, indicating safe, efficient combustion within normal operating parameters.
Dan T.
Dan T. Checked in
Performed annual heating maintenance on a 5-year-old gas furnace, including a combustion analysis with a digital analyzer under steady-state operation. Final readings showed 94.8% efficiency, 28 ppm CO, 8.31% CO₂, 6.2% O₂, a 104.6°F stack temperature, and 3.48 inH₂O manifold differential pressure, indicating safe, efficient combustion within normal operating parameters.
Toledo, OH 43615
Toledo, OH - Performed seasonal heating tune-up on an approximately 4-year-old gas furnace, with the system found operating properly and no issues or symptoms reported. Conducted combustion analysis on natural gas showing 96.8% efficiency, 7.1% O₂, 7.80% CO₂, 12 ppm CO, 95.3°F stack temperature, and 3.46 inH₂O differential pressure, confirming safe and efficient operation within normal parameters.
Dan T.
Dan T. Checked in
Performed seasonal heating tune-up on an approximately 4-year-old gas furnace, with the system found operating properly and no issues or symptoms reported. Conducted combustion analysis on natural gas showing 96.8% efficiency, 7.1% O₂, 7.80% CO₂, 12 ppm CO, 95.3°F stack temperature, and 3.46 inH₂O differential pressure, confirming safe and efficient operation within normal parameters.
Toledo, OH 43606
Installed and leveled a commercial gas furnace, verifying proper alignment and connection of the vent piping and equipment cabinet. Mounted and wired a Honeywell Home digital thermostat on the wall, then confirmed control communication and set operation to a 68°F setpoint.
Installed and leveled a commercial gas furnace, verifying proper alignment and connection of the vent piping and equipment cabinet. Mounted and wired a Honeywell Home digital thermostat on the wall, then confirmed control communication and set operation to a 68°F setpoint.
Aaron T.
Aaron T. Checked in
Installed and leveled a commercial gas furnace, verifying proper alignment and connection of the vent piping and equipment cabinet. Mounted and wired a Honeywell Home digital thermostat on the wall, then confirmed control communication and set operation to a 68°F setpoint.
Toledo, OH 43606
Toledo, OH - Performed annual maintenance on a gas-fired furnace, including a combustion analysis using a Testo 310 II and verification of gas pressure with a Testo 510i differential pressure meter. Readings were within normal operating range, with 95.5% combustion efficiency, 6.3% O₂, 8.25% CO₂, 21 ppm CO, 101.2°F stack temperature, and 3.47 inH₂O differential pressure, confirming safe and efficient furnace operation.
Dan T.
Dan T. Checked in
Performed annual maintenance on a gas-fired furnace, including a combustion analysis using a Testo 310 II and verification of gas pressure with a Testo 510i differential pressure meter. Readings were within normal operating range, with 95.5% combustion efficiency, 6.3% O₂, 8.25% CO₂, 21 ppm CO, 101.2°F stack temperature, and 3.47 inH₂O differential pressure, confirming safe and efficient furnace operation.
Toledo, OH 43613
Performed a diagnostic inspection of the boiler and AC system for a new homeowner. Combustion analysis on the natural gas boiler showed 13 ppm CO, 80.7% efficiency, 272.9°F stack temperature, and 13.7% O₂ with 168% excess air, indicating a lean, over-aired burn that is reducing efficiency and warrants burner adjustment and tuning. The R-22 AC system tested at 57.6 psi suction and 144.8 psi head pressure with 24.7°F superheat and 18.9°F subcooling, indicating the system is operating but with elevated superheat; findings were relayed to the owner, with recommendations for boiler tune-up and AC evaluation.
Performed a diagnostic inspection of the boiler and AC system for a new homeowner. Combustion analysis on the natural gas boiler showed 13 ppm CO, 80.7% efficiency, 272.9°F stack temperature, and 13.7% O₂ with 168% excess air, indicating a lean, over-aired burn that is reducing efficiency and warrants burner adjustment and tuning. The R-22 AC system tested at 57.6 psi suction and 144.8 psi head pressure with 24.7°F superheat and 18.9°F subcooling, indicating the system is operating but with elevated superheat; findings were relayed to the owner, with recommendations for boiler tune-up and AC evaluation.
Dan T.
Dan T. Checked in
Performed a diagnostic inspection of the boiler and AC system for a new homeowner. Combustion analysis on the natural gas boiler showed 13 ppm CO, 80.7% efficiency, 272.9°F stack temperature, and 13.7% O₂ with 168% excess air, indicating a lean, over-aired burn that is reducing efficiency and warrants burner adjustment and tuning. The R-22 AC system tested at 57.6 psi suction and 144.8 psi head pressure with 24.7°F superheat and 18.9°F subcooling, indicating the system is operating but with elevated superheat; findings were relayed to the owner, with recommendations for boiler tune-up and AC evaluation.
Toledo, OH 43615
Performed a routine furnace tune-up and inspected the combustion chamber, pilot assembly, and burner compartment. Verified the pilot flame was lit and burning blue, and documented significant corrosion and heat-related discoloration on the interior combustion chamber surfaces and cover plate. System was operating properly at time of service; recommend monitoring the corrosion and evaluating the unit for potential replacement given its unknown age and condition.
Performed a routine furnace tune-up and inspected the combustion chamber, pilot assembly, and burner compartment. Verified the pilot flame was lit and burning blue, and documented significant corrosion and heat-related discoloration on the interior combustion chamber surfaces and cover plate. System was operating properly at time of service; recommend monitoring the corrosion and evaluating the unit for potential replacement given its unknown age and condition.
Jeff C.
Jeff C. Checked in
Performed a routine furnace tune-up and inspected the combustion chamber, pilot assembly, and burner compartment. Verified the pilot flame was lit and burning blue, and documented significant corrosion and heat-related discoloration on the interior combustion chamber surfaces and cover plate. System was operating properly at time of service; recommend monitoring the corrosion and evaluating the unit for potential replacement given its unknown age and condition.
Toledo, OH 43615

easy-financing img

Heating & Cooling Services In Toledo, Ohio

Contact Us
easy-financing img

Heating & Cooling Services In Toledo, Ohio

What To Expect

Discover The Bluflame Service Co. Difference

Decades of Dedication

Over 70 years of commitment to providing our community with exceptional heating and cooling solutions

Same-Day Emergency Service

Reliable emergency services to address your urgent heating and cooling needs

Background-Checked Technicians

Our trusted team has the expertise and training to deliver the highest quality services every time

Flexible Financing Options

Get the comfort services you need without breaking your budget

Retail Parts on Hand

Fully stocked trucks and retail parts on demand to get your system back up and running quickly

Upfront & Honest Pricing

Straightforward and fair prices for our services without unexpected fees or upcharges

Decades of Dedication

Over 70 years of commitment to providing our community with exceptional heating and cooling solutions

Same-Day Emergency Service

Reliable emergency services to address your urgent heating and cooling needs

Background-Checked Technicians

Our trusted team has the expertise and training to deliver the highest quality services every time

Flexible Financing Options

Get the comfort services you need without breaking your budget

Retail Parts on Hand

Fully stocked trucks and retail parts on demand to get your system back up and running quickly

Upfront & Honest Pricing

Straightforward and fair prices for our services without unexpected fees or upcharges

Review Image
Our Reviews

See What Your Neighbors Are Saying

Bluflame installed a new furnace and AC unit for us. The technicians were professional and courteous. The job was done quickly and efficiently. The guys cleaned up after themselves and left no mess. When I discovered purple pipe glue had been dropped on my floor and…

M.J.

M.J.

We have used Bluflame twice in the past 3 years. Most recently in February our heater stopped working. A technician was at our home within 45 minutes. He replaced a motor and cleaned the unit, within 2 hours our heat was restored. This company has great…