From Woodlands Park to Hulls Crossing to Five Point Road, homeowners in Perrysburg need quality service they can count on. The licensed and insured team at Bluflame Service Co. provides same-day services to meet your heating, cooling, plumbing, and air quality needs.
We have the expertise to service all brands, and our upfront pricing lets you weigh your options and make the right choices for your unique home. Get started with our free service call and replacement estimates.
Don’t let home repair needs pile up — contact us now to schedule service.

Expert Air Conditioning Services
Perrysburg’s warm and humid summers make reliable cooling services vital for any home. From traditional air conditioners to ductless mini-split systems, the experts at Bluflame can ensure your comfort all summer long. Our comprehensive cooling services include:
- AC repair: Whether your air conditioner is blowing warm air or shutting down entirely, our team can address any issue with prompt, thorough repairs.
- AC installation and replacement: Whether installing an entirely new air conditioner or replacing one at the end of its life, Bluflame adheres to strict safety and quality standards when setting up your cooling system.
- AC maintenance: Waiting for service until a problem arises can lead to more costly repairs and a shorter life for your AC unit. Regular maintenance and tune-ups keep your costs low and your cooling system’s performance strong.
Professional Heating Services
The average low temperature for a Perrysburg January night is a chill 18 degrees, so you need to be sure you can count on your heater to keep running. Whether your home has a furnace, a boiler, or a heat pump, our experienced technicians provide reliable care for your heating system. Bluflame’s heating services include:
- Heating installation and replacement: Our team can help you find the right heater for your home or upgrade your current system to a more energy-efficient one.
- Heating maintenance and tune-ups: We carefully inspect your heater to prevent problems before they start, keeping your home warm and your energy bills low.
- Heating repair: When the unexpected arises, we provide swift and lasting repairs for any heater issue.
Indoor Air Quality Services in Perrysburg
Allergy season can be especially brutal in Ohio, particularly for those with tree allergies. Bluflame’s indoor air quality services protect your home from pollen, dirt, dust, pollutants, and more. In addition to our state-of-the-art air purifiers, our indoor air quality services include air scrubbers to ensure your air stays clean. Our whole-home humidifiers and dehumidifiers let you perfectly control your home’s moisture for comfort and well-being.
Reliable Water Heater Services
Your daily life depends on hot water, from the warm shower that starts your morning to the dishwasher that cleans up after dinner. At Bluflame, we service all varieties of water heaters, including traditional, gas, electric, and tankless models. Call us for water heater services when you need:
- Water heater installation: We follow the procedures to the letter so you have a perfectly installed water heater the first time.
- Water heater maintenance: Regular maintenance keeps your water heater performing well and helps you comply with many warranties.
- Water heater repair: We can handle any water heater problems so you can get back to your routine.
Why Choose Bluflame Service Co.?
Perrysburg households can count on Bluflame’s background-checked technicians for friendly, fast service for all their heating, cooling, air, and water heater needs. Our financing options make it easy to start, no matter what kind of home repair you’re looking at. Ask about our discounts for military servicemembers, veterans, and seniors.
Invest in your home comfort! Contact us today for your free estimate.
Bluflame Service Company has completed 20 jobs in Perrysburg, OH between September 2026 and October 2026. The most recent job was on October 23, 2026. Bluflame Service Company has completed 200 jobs in Perrysburg, OH in the last 12 months.Recent Jobs and Reviews in Perrysburg, OH
Perrysburg, OH at a glance
Job Locations and Reviews
Performed annual heating maintenance on a 1-year-old gas furnace, including a combustion analysis with a Testo 310 II that showed normal results (O2 7.2%, CO 12 ppm, CO2 7.74%, 95.9% efficiency). Verified gas supply and manifold pressure with a dual-port manometer (3.16 and 3.34 inWC). The furnace was operating within normal parameters at completion, with no issues found.
Responded to a no-heat call on a 6-year-old American Standard gas furnace with a non-operating blower, with a suspected failed hot surface ignitor. Inspected the furnace and verified the gas supply, condensate drain piping, flue connection, and Honeywell zone control wiring, and used a clamp meter to test electrical components and diagnose the ignition system. Documented the unit's condition, with no visible rust, damage, or leaks, and presented the customer with a maintenance plan.
Performed annual preventive maintenance on a 3–4 year old Lennox gas furnace, inspecting the cabinet, plenum, ductwork connections, PVC intake/exhaust venting, and condensate drain line and trap, with no visible rust, cracks, or damage noted. System was found operating properly with no issues reported, and the attached Carrier humidifier and adjacent water heater area were also observed in good condition.
Performed a routine tune-up on the gas furnace, including a combustion analysis with a flue gas analyzer. Readings showed a stack temperature of 103.7°F, O₂ at 7.0%, CO at 37 ppm (56 ppm air-free), CO₂ at 7.86%, excess air at 44.8%, and combustion efficiency of 94.5%. The furnace was found present and operating, with no performance issues observed.
Completed scheduled maintenance on a one-year-old residential gas furnace system during the confirmed 8:00-8:30 AM service window. Performed comprehensive heating season inspection including filter evaluation, burner assembly examination, heat exchanger inspection, blower motor operation verification, and safety control testing. All components found operating within manufacturer specifications with no deficiencies noted. System includes integrated humidifier unit and standard condensate drainage configuration. Equipment remains under warranty with no renewal required at this time.
Responded to furnace noise complaint and performed system inspection. Examined internal components including heat exchanger, blower assembly, and burner section. Documented current condition with photos showing air filtration system and internal cabinet components with evidence of operational wear and minor discoloration on metal surfaces. Noise issue remains present and requires further diagnostic evaluation to identify source and determine necessary repairs.
Completed annual furnace maintenance and tune-up on 8-year-old heating system. Performed comprehensive cleaning of furnace components, verified system operation with digital multimeter showing proper voltage readings, and tested temperature differential across heat exchanger. Inspected blower motor assembly, checked electrical connections, and confirmed all safety controls functioning within manufacturer specifications.
Completed comprehensive heating maintenance on 6-year-old natural gas furnace including full system inspection and combustion analysis. Flue gas testing with Testo 310 analyzer confirmed unit operating at 78.1% efficiency with acceptable combustion parameters: stack temperature 393.4°F, oxygen level 10.2%, carbon monoxide 44 ppm, and excess air 84.5%. All readings within manufacturer specifications for safe and efficient operation.
Completed comprehensive tune-up on 2-year-old furnace system. Performed standard maintenance procedures including filter inspection, burner assembly cleaning, heat exchanger examination, and safety control testing. All components found operating within normal parameters with no issues identified.
Completed fall cleaning and tune-up on 20-year-old residential air conditioning system. Performed comprehensive maintenance including inspection of furnace and air handler unit, checked refrigerant levels, cleaned condensate drain lines, verified thermostat operation, and inspected all electrical connections and ductwork. System operating within normal parameters with no issues identified at time of service.
Completed comprehensive heating maintenance on 8-year-old gas-powered furnace during scheduled appointment window. Performed full system diagnostics including combustion analysis using calibrated flue gas analyzer, which confirmed safe and efficient operation with readings of 110.4°F stack temperature, 2 ppm CO, 89.7% efficiency, and proper oxygen levels at 10.8%. All safety checks passed and system is operating within manufacturer specifications; customer's annual maintenance agreement has been renewed.
Completed preventative maintenance on a 9-year-old Amana gas furnace system. Performed comprehensive inspection of all components including burner assembly, heat exchanger, condensate drainage system with PVC piping, and electrical connections, confirming all systems operating within manufacturer specifications.
Completed comprehensive maintenance on 14-year-old gas heating system. Performed combustion analysis using calibrated analyzer, confirming system operating within optimal parameters with 92.3% efficiency, oxygen level at 9.0%, carbon monoxide at 3 ppm, and carbon dioxide at 6.73%.
Responded to service call for furnace making excessive noise. Upon inspection, performed combustion analysis using Testo 310 II analyzer, which revealed acceptable readings with stack temperature at 111.8°F, oxygen at 7.1%, carbon monoxide at 46 ppm, and efficiency at 93.3%. Diagnosed and resolved noise issue, ensuring unit operates within manufacturer specifications.
Completed routine furnace maintenance on 8-year-old system in preparation for heating season, including thorough cleaning, comprehensive inspection of all components, and lubrication of circulating fan motor. System found operating properly with no issues identified; recent fan motor replacement by another contractor verified and functioning as designed. Condensate drainage system inspected and confirmed operational.
Completed annual maintenance on 15-year-old gas furnace. Performed combustion analysis using Testo 310 flue gas analyzer, confirming safe and efficient operation with readings showing 95.6°F stack temperature, 10.4% oxygen, 9 ppm CO, and 94.3% efficiency. All safety and performance parameters verified within acceptable ranges.
Completed 10-year Maintenance MVP heating system inspection and service. Upon inspection, discovered significant rust and corrosion on internal metal components and housing, particularly around ductwork connections and mounting areas. Documented equipment condition with photos showing deteriorated metal surfaces and oxidation requiring monitoring for potential future component replacement.
# HVAC Service Report
Responded to no-heat call for 4-year-old Bryant HVAC system. Upon inspection, furnace was not initiating heating cycle. Performed diagnostic evaluation of the system, checked electrical connections, verified thermostat communication, and inspected ignition components. Identified and resolved issue preventing furnace operation. System tested and confirmed operational, restoring heat to entire home.
Responded to callback for new HVAC installation with customer reporting cool air escaping from multiple unsealed venting locations. Upon arrival, performed thorough inspection of ductwork system and air handler installation in mechanical room. Identified gaps in metal duct channels where green foam insulation strips were improperly seated, allowing conditioned air to bypass intended airflow paths. Verified refrigerant lines, PVC condensate drainage, and main air handler unit were properly installed per manufacturer specifications. Adjusted and properly secured foam insulation strips in vertical metal tracks adjacent to furnace unit to eliminate air leakage. Inspected all ductwork connections, supply and return plenums, and register boots throughout system for additional unsealed penetrations. Sealed identified gaps using appropriate methods to restore system efficiency and ensure proper airflow distribution. Verified system operation with no further air leakage detected at previously a
Completed comprehensive MVP maintenance service on both cooling and heating systems. Performed standard preventive maintenance procedures on outdoor condensing unit, including inspection of electrical disconnect box and verification of proper fuse installation and wiring connections. Checked unit levelness and internal components to ensure optimal system operation. Coordinated return visit required to complete furnace maintenance portion, as access to heating equipment was obstructed by appliances that need to be relocated prior to service.