Emergency Service Hours Until 12:00 AM
At Bluflame, our commitment to your comfort extends beyond regular hours. Our service ensures that whenever heating or cooling issues arise, our dedicated team is ready to address them promptly. Our skilled technicians are just a call away; call us at (419) 379-3527 to schedule a service.

HVAC & Plumbing Services in Perrysburg, OH

From Woodlands Park to Hulls Crossing to Five Point Road, homeowners in Perrysburg need quality service they can count on. The licensed and insured team at Bluflame Service Co. provides same-day services to meet your heating, cooling, plumbing, and air quality needs.

We have the expertise to service all brands, and our upfront pricing lets you weigh your options and make the right choices for your unique home. Get started with our free service call and replacement estimates.

Don’t let home repair needs pile up — contact us now to schedule service.

HVAC technician performing a heating repair service on a boiler

Expert Air Conditioning Services

Perrysburg’s warm and humid summers make reliable cooling services vital for any home. From traditional air conditioners to ductless mini-split systems, the experts at Bluflame can ensure your comfort all summer long. Our comprehensive cooling services include:

  • AC repair: Whether your air conditioner is blowing warm air or shutting down entirely, our team can address any issue with prompt, thorough repairs.
  • AC installation and replacement: Whether installing an entirely new air conditioner or replacing one at the end of its life, Bluflame adheres to strict safety and quality standards when setting up your cooling system.
  • AC maintenance: Waiting for service until a problem arises can lead to more costly repairs and a shorter life for your AC unit. Regular maintenance and tune-ups keep your costs low and your cooling system’s performance strong.

Professional Heating Services

The average low temperature for a Perrysburg January night is a chill 18 degrees, so you need to be sure you can count on your heater to keep running. Whether your home has a furnace, a boiler, or a heat pump, our experienced technicians provide reliable care for your heating system. Bluflame’s heating services include:

  • Heating installation and replacement: Our team can help you find the right heater for your home or upgrade your current system to a more energy-efficient one.
  • Heating maintenance and tune-ups: We carefully inspect your heater to prevent problems before they start, keeping your home warm and your energy bills low.
  • Heating repair: When the unexpected arises, we provide swift and lasting repairs for any heater issue.

Indoor Air Quality Services in Perrysburg

Allergy season can be especially brutal in Ohio, particularly for those with tree allergies. Bluflame’s indoor air quality services protect your home from pollen, dirt, dust, pollutants, and more. In addition to our state-of-the-art air purifiers, our indoor air quality services include air scrubbers to ensure your air stays clean. Our whole-home humidifiers and dehumidifiers let you perfectly control your home’s moisture for comfort and well-being.

Reliable Water Heater Services

Your daily life depends on hot water, from the warm shower that starts your morning to the dishwasher that cleans up after dinner. At Bluflame, we service all varieties of water heaters, including traditional, gas, electric, and tankless models. Call us for water heater services when you need:

  • Water heater installation: We follow the procedures to the letter so you have a perfectly installed water heater the first time.
  • Water heater maintenance: Regular maintenance keeps your water heater performing well and helps you comply with many warranties.
  • Water heater repair: We can handle any water heater problems so you can get back to your routine.

Why Choose Bluflame Service Co.?

Perrysburg households can count on Bluflame’s background-checked technicians for friendly, fast service for all their heating, cooling, air, and water heater needs. Our financing options make it easy to start, no matter what kind of home repair you’re looking at. Ask about our discounts for military servicemembers, veterans, and seniors.

Invest in your home comfort! Contact us today for your free estimate.  

 

Recent Jobs and Reviews in Perrysburg, OH

Perrysburg, OH at a glance

Bluflame Service Company has completed 20 jobs in Perrysburg, OH between August 2026 and September 2026.

The most recent job was on September 15, 2026.

Bluflame Service Company has completed 200 jobs in Perrysburg, OH in the last 12 months.

Job Locations and Reviews

Completed full HVAC system installation in residential basement mechanical room, including 90% efficiency B cabinet upflow furnace rated at 75,000 BTU/h with Lennox branding. Installed 2.5/3 ton cased evaporator coil (B configuration) mounted to furnace plenum with proper refrigerant connections. Set 2.5 ton outdoor condensing unit on new leveled ground pad, relocating unit 3 feet from outdoor electrical meter per specifications. Ran 30'+ refrigerant line set (3/8"-3/4") with proper insulation from outdoor condenser to indoor coil, ensuring leak-free brazed connections at all joints. Installed 30 amp electrical disconnect at outdoor unit with 12' electrical insulation whip for flexible connection. Wired 240v/24v electrical junction box to provide power and control voltage to system. Installed S-40 7" smart thermostat with programming capabilities for system control. Routed white PVC condensate drain lines from furnace with proper pitch and termination. Verified all electrical connectio
Completed full HVAC system installation in residential basement mechanical room, including 90% efficiency B cabinet upflow furnace rated at 75,000 BTU/h with Lennox branding. Installed 2.5/3 ton cased evaporator coil (B configuration) mounted to furnace plenum with proper refrigerant connections. Set 2.5 ton outdoor condensing unit on new leveled ground pad, relocating unit 3 feet from outdoor electrical meter per specifications. Ran 30'+ refrigerant line set (3/8"-3/4") with proper insulation from outdoor condenser to indoor coil, ensuring leak-free brazed connections at all joints. Installed 30 amp electrical disconnect at outdoor unit with 12' electrical insulation whip for flexible connection. Wired 240v/24v electrical junction box to provide power and control voltage to system. Installed S-40 7" smart thermostat with programming capabilities for system control. Routed white PVC condensate drain lines from furnace with proper pitch and termination. Verified all electrical connectio
Aaron T.
Aaron T. Checked in
Completed full HVAC system installation in residential basement mechanical room, including 90% efficiency B cabinet upflow furnace rated at 75,000 BTU/h with Lennox branding. Installed 2.5/3 ton cased evaporator coil (B configuration) mounted to furnace plenum with proper refrigerant connections. Set 2.5 ton outdoor condensing unit on new leveled ground pad, relocating unit 3 feet from outdoor electrical meter per specifications. Ran 30'+ refrigerant line set (3/8"-3/4") with proper insulation from outdoor condenser to indoor coil, ensuring leak-free brazed connections at all joints. Installed 30 amp electrical disconnect at outdoor unit with 12' electrical insulation whip for flexible connection. Wired 240v/24v electrical junction box to provide power and control voltage to system. Installed S-40 7" smart thermostat with programming capabilities for system control. Routed white PVC condensate drain lines from furnace with proper pitch and termination. Verified all electrical connectio
Perrysburg, OH 43551
Completed installation of Lennox ML196 90,000 BTU upflow gas furnace in basement mechanical room. Removed existing furnace and replaced deteriorated return air boot assembly due to extensive rust damage. Installed new galvanized sheet metal return plenum and boot connection to ensure proper airflow and system integrity.

Ran new PVC exhaust and intake venting system in accordance with manufacturer specifications for 90%+ AFUE condensing furnace operation. Venting routed through basement ceiling joists and terminated through exterior wall. All PVC joints properly primed, glued, and secured with appropriate hangers and supports.

Installed new thermostat and completed all necessary electrical connections. Performed system startup, verified proper ignition sequence, flame characteristics, and burner operation. Confirmed adequate combustion air supply and proper condensate drainage. System tested and operating within manufacturer specifications.
Completed installation of Lennox ML196 90,000 BTU upflow gas furnace in basement mechanical room. Removed existing furnace and replaced deteriorated return air boot assembly due to extensive rust damage. Installed new galvanized sheet metal return plenum and boot connection to ensure proper airflow and system integrity.

Ran new PVC exhaust and intake venting system in accordance with manufacturer specifications for 90%+ AFUE condensing furnace operation. Venting routed through basement ceiling joists and terminated through exterior wall. All PVC joints properly primed, glued, and secured with appropriate hangers and supports.

Installed new thermostat and completed all necessary electrical connections. Performed system startup, verified proper ignition sequence, flame characteristics, and burner operation. Confirmed adequate combustion air supply and proper condensate drainage. System tested and operating within manufacturer specifications.
Dakota S.
Dakota S. Checked in
Completed installation of Lennox ML196 90,000 BTU upflow gas furnace in basement mechanical room. Removed existing furnace and replaced deteriorated return air boot assembly due to extensive rust damage. Installed new galvanized sheet metal return plenum and boot connection to ensure proper airflow and system integrity. Ran new PVC exhaust and intake venting system in accordance with manufacturer specifications for 90%+ AFUE condensing furnace operation. Venting routed through basement ceiling joists and terminated through exterior wall. All PVC joints properly primed, glued, and secured with appropriate hangers and supports. Installed new thermostat and completed all necessary electrical connections. Performed system startup, verified proper ignition sequence, flame characteristics, and burner operation. Confirmed adequate combustion air supply and proper condensate drainage. System tested and operating within manufacturer specifications.
Perrysburg, OH 43551
Completed scheduled heating maintenance on a 1.5-year-old Carrier furnace system. Performed comprehensive inspection of all internal components including blower motor assembly, control board, electrical connections, and safety systems. All equipment found operating within normal parameters with no deficiencies noted at time of service.
Completed scheduled heating maintenance on a 1.5-year-old Carrier furnace system. Performed comprehensive inspection of all internal components including blower motor assembly, control board, electrical connections, and safety systems. All equipment found operating within normal parameters with no deficiencies noted at time of service.
Jeff C.
Jeff C. Checked in
Completed scheduled heating maintenance on a 1.5-year-old Carrier furnace system. Performed comprehensive inspection of all internal components including blower motor assembly, control board, electrical connections, and safety systems. All equipment found operating within normal parameters with no deficiencies noted at time of service.
Perrysburg, OH 43551
Completed comprehensive estimate for full HVAC system replacement at residential property. Evaluated existing Amana furnace installation located in basement utility area with interconnected air handler and evaporator coil assembly. Assessed current system configuration including white PVC condensate drainage piping, ductwork connections, and ventilation components within confined mechanical space. Inspected outdoor condensing unit positioned on concrete pad against home exterior with proper clearances from structure. Unit currently installed in mulched area adjacent to white vinyl siding with electrical service panel and meter mounted above on exterior wall. Documented complete system layout including refrigerant line set routing, electrical connections, and overall equipment condition. Photographed indoor furnace assembly showing vertical installation with top-mounted coil configuration and multiple PVC pipe connections for combustion air and condensate removal. Captured outdoor unit
Completed comprehensive estimate for full HVAC system replacement at residential property. Evaluated existing Amana furnace installation located in basement utility area with interconnected air handler and evaporator coil assembly. Assessed current system configuration including white PVC condensate drainage piping, ductwork connections, and ventilation components within confined mechanical space. Inspected outdoor condensing unit positioned on concrete pad against home exterior with proper clearances from structure. Unit currently installed in mulched area adjacent to white vinyl siding with electrical service panel and meter mounted above on exterior wall. Documented complete system layout including refrigerant line set routing, electrical connections, and overall equipment condition. Photographed indoor furnace assembly showing vertical installation with top-mounted coil configuration and multiple PVC pipe connections for combustion air and condensate removal. Captured outdoor unit
Gabe S.
Gabe S. Checked in
Completed comprehensive estimate for full HVAC system replacement at residential property. Evaluated existing Amana furnace installation located in basement utility area with interconnected air handler and evaporator coil assembly. Assessed current system configuration including white PVC condensate drainage piping, ductwork connections, and ventilation components within confined mechanical space. Inspected outdoor condensing unit positioned on concrete pad against home exterior with proper clearances from structure. Unit currently installed in mulched area adjacent to white vinyl siding with electrical service panel and meter mounted above on exterior wall. Documented complete system layout including refrigerant line set routing, electrical connections, and overall equipment condition. Photographed indoor furnace assembly showing vertical installation with top-mounted coil configuration and multiple PVC pipe connections for combustion air and condensate removal. Captured outdoor unit
Perrysburg, OH 43551
# HVAC Service Report - No Cooling Issue

Responded to service call for 10-year-old air conditioning system that stopped operating immediately following routine annual maintenance. Upon arrival, performed diagnostic assessment of outdoor condensing unit and associated electrical components.

Investigation revealed that the external disconnect switch had been left in the OFF position following the previous maintenance visit. The disconnect box, mounted on exterior siding, showed the switch clearly positioned to OFF as visible in documentation photos. This external safety disconnect is a standard component that allows technicians to de-energize the unit during service work.

Verified that all other system components appeared intact with no visible damage to wiring, conduit, or the disconnect enclosure itself. The unit had adequate power supply to the disconnect location, and no tripped breakers were found at the main electrical panel.

Corrected the issue by returning the disconnect swit
# HVAC Service Report - No Cooling Issue

Responded to service call for 10-year-old air conditioning system that stopped operating immediately following routine annual maintenance. Upon arrival, performed diagnostic assessment of outdoor condensing unit and associated electrical components.

Investigation revealed that the external disconnect switch had been left in the OFF position following the previous maintenance visit. The disconnect box, mounted on exterior siding, showed the switch clearly positioned to OFF as visible in documentation photos. This external safety disconnect is a standard component that allows technicians to de-energize the unit during service work.

Verified that all other system components appeared intact with no visible damage to wiring, conduit, or the disconnect enclosure itself. The unit had adequate power supply to the disconnect location, and no tripped breakers were found at the main electrical panel.

Corrected the issue by returning the disconnect swit
Jeff C.
Jeff C. Checked in
# HVAC Service Report - No Cooling Issue Responded to service call for 10-year-old air conditioning system that stopped operating immediately following routine annual maintenance. Upon arrival, performed diagnostic assessment of outdoor condensing unit and associated electrical components. Investigation revealed that the external disconnect switch had been left in the OFF position following the previous maintenance visit. The disconnect box, mounted on exterior siding, showed the switch clearly positioned to OFF as visible in documentation photos. This external safety disconnect is a standard component that allows technicians to de-energize the unit during service work. Verified that all other system components appeared intact with no visible damage to wiring, conduit, or the disconnect enclosure itself. The unit had adequate power supply to the disconnect location, and no tripped breakers were found at the main electrical panel. Corrected the issue by returning the disconnect swit
Perrysburg, OH 43551
# HVAC Service Completed

Responded to service call for 16-year-old air conditioning system with reduced airflow and insufficient cooling throughout home. Customer reported drain functioning properly and filter recently replaced.

Upon arrival, performed comprehensive system diagnostics. Accessed electrical panel to inspect power supply and circuit protection for outdoor condensing unit. Panel inspection revealed significant accumulation of dust, debris, and cobwebs indicating lack of recent maintenance, though all circuit breakers were functioning properly and connections were secure.

Proceeded to outdoor unit for electrical testing. Using digital clamp meter, measured amperage draw on compressor circuit, which registered 0.50 amps—significantly below normal operating range for a residential AC compressor. This abnormally low amperage reading indicated compressor failure or loss of refrigerant charge preventing compressor from running under load.

Given the age of the system at 16 ye
# HVAC Service Completed

Responded to service call for 16-year-old air conditioning system with reduced airflow and insufficient cooling throughout home. Customer reported drain functioning properly and filter recently replaced.

Upon arrival, performed comprehensive system diagnostics. Accessed electrical panel to inspect power supply and circuit protection for outdoor condensing unit. Panel inspection revealed significant accumulation of dust, debris, and cobwebs indicating lack of recent maintenance, though all circuit breakers were functioning properly and connections were secure.

Proceeded to outdoor unit for electrical testing. Using digital clamp meter, measured amperage draw on compressor circuit, which registered 0.50 amps—significantly below normal operating range for a residential AC compressor. This abnormally low amperage reading indicated compressor failure or loss of refrigerant charge preventing compressor from running under load.

Given the age of the system at 16 ye
Jeff C.
Jeff C. Checked in
# HVAC Service Completed Responded to service call for 16-year-old air conditioning system with reduced airflow and insufficient cooling throughout home. Customer reported drain functioning properly and filter recently replaced. Upon arrival, performed comprehensive system diagnostics. Accessed electrical panel to inspect power supply and circuit protection for outdoor condensing unit. Panel inspection revealed significant accumulation of dust, debris, and cobwebs indicating lack of recent maintenance, though all circuit breakers were functioning properly and connections were secure. Proceeded to outdoor unit for electrical testing. Using digital clamp meter, measured amperage draw on compressor circuit, which registered 0.50 amps—significantly below normal operating range for a residential AC compressor. This abnormally low amperage reading indicated compressor failure or loss of refrigerant charge preventing compressor from running under load. Given the age of the system at 16 ye
Perrysburg, OH 43551
Responded to emergency no cooling call for 24-year-old residential air conditioning system. Upon arrival, performed diagnostic evaluation of the outdoor condensing unit and assessed overall system condition given the age of the equipment. Documented the existing HVAC installation with the condensing unit positioned on concrete pad against exterior wall with proper electrical service connection via meter and disconnect switch. Given the advanced age of the unit at 24 years—well beyond typical equipment lifespan of 15-20 years—discussed system condition and replacement options with homeowner, as repairs on equipment of this vintage often prove cost-prohibitive and parts availability becomes increasingly limited.
Responded to emergency no cooling call for 24-year-old residential air conditioning system. Upon arrival, performed diagnostic evaluation of the outdoor condensing unit and assessed overall system condition given the age of the equipment. Documented the existing HVAC installation with the condensing unit positioned on concrete pad against exterior wall with proper electrical service connection via meter and disconnect switch. Given the advanced age of the unit at 24 years—well beyond typical equipment lifespan of 15-20 years—discussed system condition and replacement options with homeowner, as repairs on equipment of this vintage often prove cost-prohibitive and parts availability becomes increasingly limited.
Levi S.
Levi S. Checked in
Responded to emergency no cooling call for 24-year-old residential air conditioning system. Upon arrival, performed diagnostic evaluation of the outdoor condensing unit and assessed overall system condition given the age of the equipment. Documented the existing HVAC installation with the condensing unit positioned on concrete pad against exterior wall with proper electrical service connection via meter and disconnect switch. Given the advanced age of the unit at 24 years—well beyond typical equipment lifespan of 15-20 years—discussed system condition and replacement options with homeowner, as repairs on equipment of this vintage often prove cost-prohibitive and parts availability becomes increasingly limited.
Perrysburg, OH 43551
Completed full HVAC system installation including upflow cased coil in cabinet configuration utilizing existing ductboard infrastructure. Installed new 3/4-inch refrigerant line set with 30-foot run to accommodate repositioned outdoor condensing unit. Relocated Lennox condenser unit 3 feet from gas meter to meet safety clearance requirements and mounted equipment on new concrete pad. Installed new electrical disconnect and whip for proper power supply to outdoor unit. Successfully reused existing Ecobee thermostat, verifying compatibility and proper communication with new system. All refrigerant lines properly insulated and secured, system charged to manufacturer specifications, and unit tested for proper operation across all modes.
Completed full HVAC system installation including upflow cased coil in cabinet configuration utilizing existing ductboard infrastructure. Installed new 3/4-inch refrigerant line set with 30-foot run to accommodate repositioned outdoor condensing unit. Relocated Lennox condenser unit 3 feet from gas meter to meet safety clearance requirements and mounted equipment on new concrete pad. Installed new electrical disconnect and whip for proper power supply to outdoor unit. Successfully reused existing Ecobee thermostat, verifying compatibility and proper communication with new system. All refrigerant lines properly insulated and secured, system charged to manufacturer specifications, and unit tested for proper operation across all modes.
Aaron T.
Aaron T. Checked in
Completed full HVAC system installation including upflow cased coil in cabinet configuration utilizing existing ductboard infrastructure. Installed new 3/4-inch refrigerant line set with 30-foot run to accommodate repositioned outdoor condensing unit. Relocated Lennox condenser unit 3 feet from gas meter to meet safety clearance requirements and mounted equipment on new concrete pad. Installed new electrical disconnect and whip for proper power supply to outdoor unit. Successfully reused existing Ecobee thermostat, verifying compatibility and proper communication with new system. All refrigerant lines properly insulated and secured, system charged to manufacturer specifications, and unit tested for proper operation across all modes.
Perrysburg, OH 43551
Perrysburg, OH - Provided comprehensive estimate for replacement of existing Coleman furnace and separate estimate for complete HVAC system replacement. Assessed current basement installation including furnace unit with PVC venting, water heater, and metal ductwork distribution system. Noted hazardous water accumulation with slime buildup in front of furnace creating slippery conditions requiring immediate attention during any future installation work.
Gabe S.
Gabe S. Checked in
Provided comprehensive estimate for replacement of existing Coleman furnace and separate estimate for complete HVAC system replacement. Assessed current basement installation including furnace unit with PVC venting, water heater, and metal ductwork distribution system. Noted hazardous water accumulation with slime buildup in front of furnace creating slippery conditions requiring immediate attention during any future installation work.
Perrysburg, OH 43551
Responded to service call for furnace experiencing moisture issues during operation. Upon inspection, found condensate drainage system requiring attention with PVC vent pipes showing signs of water infiltration. Verified proper operation of furnace components, checked condensate trap and drainage lines, and ensured all venting connections were secure to prevent future moisture problems.
Responded to service call for furnace experiencing moisture issues during operation. Upon inspection, found condensate drainage system requiring attention with PVC vent pipes showing signs of water infiltration. Verified proper operation of furnace components, checked condensate trap and drainage lines, and ensured all venting connections were secure to prevent future moisture problems.
Jeff M.
Jeff M. Checked in
Responded to service call for furnace experiencing moisture issues during operation. Upon inspection, found condensate drainage system requiring attention with PVC vent pipes showing signs of water infiltration. Verified proper operation of furnace components, checked condensate trap and drainage lines, and ensured all venting connections were secure to prevent future moisture problems.
Perrysburg, OH 43551
Conducted comprehensive assessment of existing residential HVAC system for air conditioning replacement estimate. Evaluated current Lennox furnace installation in basement utility area, including ductwork configuration, condensate drainage system, and overall equipment accessibility. Documented outdoor condenser unit positioned against exterior brick wall, noting unit age, condition, and electrical service connections. Assessed existing infrastructure including gas meter proximity, electrical junction box placement, and drainage considerations. Photographed indoor and outdoor components to provide detailed documentation for replacement equipment specifications and installation planning.
Conducted comprehensive assessment of existing residential HVAC system for air conditioning replacement estimate. Evaluated current Lennox furnace installation in basement utility area, including ductwork configuration, condensate drainage system, and overall equipment accessibility. Documented outdoor condenser unit positioned against exterior brick wall, noting unit age, condition, and electrical service connections. Assessed existing infrastructure including gas meter proximity, electrical junction box placement, and drainage considerations. Photographed indoor and outdoor components to provide detailed documentation for replacement equipment specifications and installation planning.
Gabe S.
Gabe S. Checked in
Conducted comprehensive assessment of existing residential HVAC system for air conditioning replacement estimate. Evaluated current Lennox furnace installation in basement utility area, including ductwork configuration, condensate drainage system, and overall equipment accessibility. Documented outdoor condenser unit positioned against exterior brick wall, noting unit age, condition, and electrical service connections. Assessed existing infrastructure including gas meter proximity, electrical junction box placement, and drainage considerations. Photographed indoor and outdoor components to provide detailed documentation for replacement equipment specifications and installation planning.
Perrysburg, OH 43551
Completed comprehensive AC tune-up on outdoor condensing unit, including inspection of compressor, electrical connections, and base compartment. Verified proper operation of all components, checked refrigerant levels, cleaned debris from base pan, and confirmed electrical disconnect box functionality. Unit tested and operating within normal parameters.
Completed comprehensive AC tune-up on outdoor condensing unit, including inspection of compressor, electrical connections, and base compartment. Verified proper operation of all components, checked refrigerant levels, cleaned debris from base pan, and confirmed electrical disconnect box functionality. Unit tested and operating within normal parameters.
Darrell W.
Darrell W. Checked in
Completed comprehensive AC tune-up on outdoor condensing unit, including inspection of compressor, electrical connections, and base compartment. Verified proper operation of all components, checked refrigerant levels, cleaned debris from base pan, and confirmed electrical disconnect box functionality. Unit tested and operating within normal parameters.
Perrysburg, OH 43551
Completed comprehensive tune-up service on residential HVAC system including air conditioning and gas furnace units. Performed full inspection of electrical components, verified proper operation of TITAN PRO 40+5 MFD dual run capacitor and contactor assembly, checked all electrical connections and wiring integrity. Inspected furnace cabinet, ductwork plenum, and air handler components to ensure system is operating efficiently and safely for the upcoming season.
Completed comprehensive tune-up service on residential HVAC system including air conditioning and gas furnace units. Performed full inspection of electrical components, verified proper operation of TITAN PRO 40+5 MFD dual run capacitor and contactor assembly, checked all electrical connections and wiring integrity. Inspected furnace cabinet, ductwork plenum, and air handler components to ensure system is operating efficiently and safely for the upcoming season.
Jeff C.
Jeff C. Checked in
Completed comprehensive tune-up service on residential HVAC system including air conditioning and gas furnace units. Performed full inspection of electrical components, verified proper operation of TITAN PRO 40+5 MFD dual run capacitor and contactor assembly, checked all electrical connections and wiring integrity. Inspected furnace cabinet, ductwork plenum, and air handler components to ensure system is operating efficiently and safely for the upcoming season.
Perrysburg, OH 43551
Conducted on-site assessment for mini split system installation in a basement living area and evaluated exterior wall mounting location. Documented interior space layout and existing HVAC infrastructure including outdoor condenser unit positioning, electrical service panel, and available wall space for indoor air handler placement.
Conducted on-site assessment for mini split system installation in a basement living area and evaluated exterior wall mounting location. Documented interior space layout and existing HVAC infrastructure including outdoor condenser unit positioning, electrical service panel, and available wall space for indoor air handler placement.
Gabe S.
Gabe S. Checked in
Conducted on-site assessment for mini split system installation in a basement living area and evaluated exterior wall mounting location. Documented interior space layout and existing HVAC infrastructure including outdoor condenser unit positioning, electrical service panel, and available wall space for indoor air handler placement.
Perrysburg, OH 43551
Conducted comprehensive on-site assessment of existing HVAC system to provide replacement estimate for both furnace and air conditioning units. Evaluated current equipment configuration, including furnace installation in mechanical room with associated ductwork, venting, and PVC drainage systems. Documented existing system layout, clearances, and utility connections through detailed photography to ensure accurate equipment sizing and replacement planning. Assessment included examination of current furnace condition, air handler setup, existing duct infrastructure, and available space for new equipment installation to develop complete replacement proposal.
Conducted comprehensive on-site assessment of existing HVAC system to provide replacement estimate for both furnace and air conditioning units. Evaluated current equipment configuration, including furnace installation in mechanical room with associated ductwork, venting, and PVC drainage systems. Documented existing system layout, clearances, and utility connections through detailed photography to ensure accurate equipment sizing and replacement planning. Assessment included examination of current furnace condition, air handler setup, existing duct infrastructure, and available space for new equipment installation to develop complete replacement proposal.
Gabe S.
Gabe S. Checked in
Conducted comprehensive on-site assessment of existing HVAC system to provide replacement estimate for both furnace and air conditioning units. Evaluated current equipment configuration, including furnace installation in mechanical room with associated ductwork, venting, and PVC drainage systems. Documented existing system layout, clearances, and utility connections through detailed photography to ensure accurate equipment sizing and replacement planning. Assessment included examination of current furnace condition, air handler setup, existing duct infrastructure, and available space for new equipment installation to develop complete replacement proposal.
Perrysburg, OH 43551
Perrysburg, OH - Completed annual preventative maintenance on 7-year-old furnace and air conditioning system. Performed comprehensive AC tune-up including refrigerant level check, electrical component inspection, and condenser coil cleaning. Conducted combustion analysis on gas furnace using calibrated flue gas analyzer, confirming optimal performance with efficiency reading of 95.1%, oxygen level at 5.5%, carbon monoxide at safe level of 1.5 ppm, and CO₂ at 8.70%. All safety controls tested and verified operational. System operating within manufacturer specifications with no deficiencies noted.
Jeff C.
Jeff C. Checked in
Completed annual preventative maintenance on 7-year-old furnace and air conditioning system. Performed comprehensive AC tune-up including refrigerant level check, electrical component inspection, and condenser coil cleaning. Conducted combustion analysis on gas furnace using calibrated flue gas analyzer, confirming optimal performance with efficiency reading of 95.1%, oxygen level at 5.5%, carbon monoxide at safe level of 1.5 ppm, and CO₂ at 8.70%. All safety controls tested and verified operational. System operating within manufacturer specifications with no deficiencies noted.
Perrysburg, OH 43551
Completed comprehensive HVAC system tune-up including full system inspection and filter evaluation. Inspected water heater utility connections, gas line installation, and associated plumbing components to ensure proper clearances and safe operation of mechanical systems. Verified air filter condition in return air housing, confirmed proper installation and adequate airflow through pleated media filtration system.
Completed comprehensive HVAC system tune-up including full system inspection and filter evaluation. Inspected water heater utility connections, gas line installation, and associated plumbing components to ensure proper clearances and safe operation of mechanical systems. Verified air filter condition in return air housing, confirmed proper installation and adequate airflow through pleated media filtration system.
Levi S.
Levi S. Checked in
Completed comprehensive HVAC system tune-up including full system inspection and filter evaluation. Inspected water heater utility connections, gas line installation, and associated plumbing components to ensure proper clearances and safe operation of mechanical systems. Verified air filter condition in return air housing, confirmed proper installation and adequate airflow through pleated media filtration system.
Perrysburg, OH 43551
Perrysburg, OH - Responded to service call for air conditioning unit with recurring condensate drain line leak in basement. Inspected HVAC drainage system and identified leak at PVC condensate pipe connections. Secured loose fittings, cleaned condensate drain line, and reinforced pipe mounting with hose clamps to prevent future leakage from the 10+ year old system.
Dan T.
Dan T. Checked in
Responded to service call for air conditioning unit with recurring condensate drain line leak in basement. Inspected HVAC drainage system and identified leak at PVC condensate pipe connections. Secured loose fittings, cleaned condensate drain line, and reinforced pipe mounting with hose clamps to prevent future leakage from the 10+ year old system.
Perrysburg, OH 43551
Provided estimate for conversion of existing gas-fired Bradford White water heater to new 40-gallon electric unit, including assessment of electrical supply requirements and necessary modifications to accommodate electric heating elements. Evaluated existing plumbing connections, shut-off valves, and supply lines in confined utility space for compatibility with proposed electric water heater installation and identified additional plumbing services needed to complete the conversion.
Provided estimate for conversion of existing gas-fired Bradford White water heater to new 40-gallon electric unit, including assessment of electrical supply requirements and necessary modifications to accommodate electric heating elements. Evaluated existing plumbing connections, shut-off valves, and supply lines in confined utility space for compatibility with proposed electric water heater installation and identified additional plumbing services needed to complete the conversion.
Aaron T.
Aaron T. Checked in
Provided estimate for conversion of existing gas-fired Bradford White water heater to new 40-gallon electric unit, including assessment of electrical supply requirements and necessary modifications to accommodate electric heating elements. Evaluated existing plumbing connections, shut-off valves, and supply lines in confined utility space for compatibility with proposed electric water heater installation and identified additional plumbing services needed to complete the conversion.
Perrysburg, OH 43551
Completed standard AC tune-up service on residential cooling system. Inspected exterior disconnect box, noting significant rust and corrosion on housing and mounting components; fuses operational but enclosure shows weathering from moisture exposure. Evaluated outdoor condensing unit and associated refrigerant lines, electrical connections, and conduit routing along exterior wall.
Completed standard AC tune-up service on residential cooling system. Inspected exterior disconnect box, noting significant rust and corrosion on housing and mounting components; fuses operational but enclosure shows weathering from moisture exposure. Evaluated outdoor condensing unit and associated refrigerant lines, electrical connections, and conduit routing along exterior wall.
Darrell W.
Darrell W. Checked in
Completed standard AC tune-up service on residential cooling system. Inspected exterior disconnect box, noting significant rust and corrosion on housing and mounting components; fuses operational but enclosure shows weathering from moisture exposure. Evaluated outdoor condensing unit and associated refrigerant lines, electrical connections, and conduit routing along exterior wall.
Perrysburg, OH 43551

easy-financing img

Heating & Cooling Services In Toledo, Ohio

Contact Us
easy-financing img

Heating & Cooling Services In Toledo, Ohio

What To Expect

Discover The Bluflame Service Co. Difference

Decades of Dedication

Over 70 years of commitment to providing our community with exceptional heating and cooling solutions

Same-Day Emergency Service

Reliable emergency services to address your urgent heating and cooling needs

Background-Checked Technicians

Our trusted team has the expertise and training to deliver the highest quality services every time

Flexible Financing Options

Get the comfort services you need without breaking your budget

Retail Parts on Hand

Fully stocked trucks and retail parts on demand to get your system back up and running quickly

Upfront & Honest Pricing

Straightforward and fair prices for our services without unexpected fees or upcharges

Decades of Dedication

Over 70 years of commitment to providing our community with exceptional heating and cooling solutions

Same-Day Emergency Service

Reliable emergency services to address your urgent heating and cooling needs

Background-Checked Technicians

Our trusted team has the expertise and training to deliver the highest quality services every time

Flexible Financing Options

Get the comfort services you need without breaking your budget

Retail Parts on Hand

Fully stocked trucks and retail parts on demand to get your system back up and running quickly

Upfront & Honest Pricing

Straightforward and fair prices for our services without unexpected fees or upcharges

Review Image
Our Reviews

See What Your Neighbors Are Saying

Bluflame installed a new furnace and AC unit for us. The technicians were professional and courteous. The job was done quickly and efficiently. The guys cleaned up after themselves and left no mess. When I discovered purple pipe glue had been dropped on my floor and…

M.J.

M.J.

We have used Bluflame twice in the past 3 years. Most recently in February our heater stopped working. A technician was at our home within 45 minutes. He replaced a motor and cleaned the unit, within 2 hours our heat was restored. This company has great…

A.G.

A.G.

"Thank you, Bluflame. Customer service is everything! Many, many thanks!”

M.P., Toledo, OH

M.P., Toledo, OH

"We were pleased with the very fair price and the quick installation on short notice."

M.R., Curtice, OH

M.R., Curtice, OH