From Woodlands Park to Hulls Crossing to Five Point Road, homeowners in Perrysburg need quality service they can count on. The licensed and insured team at Bluflame Service Co. provides same-day services to meet your heating, cooling, plumbing, and air quality needs.
We have the expertise to service all brands, and our upfront pricing lets you weigh your options and make the right choices for your unique home. Get started with our free service call and replacement estimates.
Don’t let home repair needs pile up — contact us now to schedule service.

Expert Air Conditioning Services
Perrysburg’s warm and humid summers make reliable cooling services vital for any home. From traditional air conditioners to ductless mini-split systems, the experts at Bluflame can ensure your comfort all summer long. Our comprehensive cooling services include:
- AC repair: Whether your air conditioner is blowing warm air or shutting down entirely, our team can address any issue with prompt, thorough repairs.
- AC installation and replacement: Whether installing an entirely new air conditioner or replacing one at the end of its life, Bluflame adheres to strict safety and quality standards when setting up your cooling system.
- AC maintenance: Waiting for service until a problem arises can lead to more costly repairs and a shorter life for your AC unit. Regular maintenance and tune-ups keep your costs low and your cooling system’s performance strong.
Professional Heating Services
The average low temperature for a Perrysburg January night is a chill 18 degrees, so you need to be sure you can count on your heater to keep running. Whether your home has a furnace, a boiler, or a heat pump, our experienced technicians provide reliable care for your heating system. Bluflame’s heating services include:
- Heating installation and replacement: Our team can help you find the right heater for your home or upgrade your current system to a more energy-efficient one.
- Heating maintenance and tune-ups: We carefully inspect your heater to prevent problems before they start, keeping your home warm and your energy bills low.
- Heating repair: When the unexpected arises, we provide swift and lasting repairs for any heater issue.
Indoor Air Quality Services in Perrysburg
Allergy season can be especially brutal in Ohio, particularly for those with tree allergies. Bluflame’s indoor air quality services protect your home from pollen, dirt, dust, pollutants, and more. In addition to our state-of-the-art air purifiers, our indoor air quality services include air scrubbers to ensure your air stays clean. Our whole-home humidifiers and dehumidifiers let you perfectly control your home’s moisture for comfort and well-being.
Reliable Water Heater Services
Your daily life depends on hot water, from the warm shower that starts your morning to the dishwasher that cleans up after dinner. At Bluflame, we service all varieties of water heaters, including traditional, gas, electric, and tankless models. Call us for water heater services when you need:
- Water heater installation: We follow the procedures to the letter so you have a perfectly installed water heater the first time.
- Water heater maintenance: Regular maintenance keeps your water heater performing well and helps you comply with many warranties.
- Water heater repair: We can handle any water heater problems so you can get back to your routine.
Why Choose Bluflame Service Co.?
Perrysburg households can count on Bluflame’s background-checked technicians for friendly, fast service for all their heating, cooling, air, and water heater needs. Our financing options make it easy to start, no matter what kind of home repair you’re looking at. Ask about our discounts for military servicemembers, veterans, and seniors.
Invest in your home comfort! Contact us today for your free estimate.
Recent Jobs and Reviews in Perrysburg, OH
Job Locations and Reviews
Completed comprehensive boiler system estimate for existing hydronic heating installation featuring expansion tank, multi-zone copper piping network, and integrated water heating components. Documented current system configuration including PVC venting, zone valving, control mechanisms, and all mechanical connections to provide accurate replacement specifications and equipment recommendations.
Completed comprehensive AC tune-up service including full system inspection and performance verification. Inspected basement HVAC equipment including Aprilaire humidifier unit, ductwork connections, and electrical components; checked exterior condensing unit electrical connections and terminals for proper contact and secure mounting. Customer requested membership renewal at time of service visit.
Installed Lennox commercial unit heater in greenhouse facility to provide climate control for agricultural operations. Unit was mounted on metal support frame with wooden pallet base over gravel flooring, including installation of all necessary electrical connections, gas piping, venting components, and digital thermostat control panel. System was tested and verified operational upon completion.
Completed spring maintenance and tune-up on a 10-year-old residential air conditioning system. Performed comprehensive inspection of outdoor condenser unit, including electrical connections, capacitor, and fan motor assembly. All components found to be operational with system functioning within normal parameters.
Completed spring maintenance and tune-up on a 3-year-old air conditioning system. Inspected and verified proper operation of electrical disconnect box with cartridge fuses, checked capacitor connections and wiring harness integrity, and documented system condition through photos. All components found in good working order with no immediate repairs needed.
Conducted comprehensive furnace replacement estimate for residential forced-air heating system. Documented existing cabinet-style furnace unit with accessible blower motor assembly, control board, PVC venting system, and electrical components to provide accurate replacement specifications and equipment recommendations.
Completed routine cooling maintenance on outdoor air conditioning condenser unit. Performed comprehensive system inspection including electrical components, capacitor testing, and verification of all wire connections within the control compartment. All components found to be operating within normal parameters, unit tested and confirmed functioning properly.
Completed routine air conditioning tune-up on 5-year-old Amana outdoor condensing unit. Performed standard maintenance inspection including checking refrigerant levels, cleaning condenser coils, testing electrical connections, and verifying proper system operation. Unit found to be in good working condition with no immediate repairs needed.
Responded to no heat call where homeowner suspected failed inducer motor. Upon inspection, discovered severely deteriorated and cracked pressure switch assembly with significant corrosion and mineral deposits throughout the combustion chamber area. The pressure switch diaphragm had failed, preventing the furnace from completing its ignition sequence. Replaced faulty pressure switch, cleaned combustion chamber deposits, and verified proper system operation through multiple heating cycles. Unit restored to full functionality with normal heat output confirmed.
Completed scheduled cooling maintenance visit on 3-year-old Lennox outdoor condensing unit. Performed comprehensive system inspection including electrical components, capacitors, and wiring connections. All components found in proper working condition with no immediate service needs identified. Unit operating within normal parameters for continued reliable cooling performance.
Performed comprehensive seasonal tune-up and maintenance inspection on 23-year-old residential air conditioning system. Evaluated outdoor condenser unit operation, checked refrigerant lines and connections, inspected indoor air handler components, and verified system functionality to ensure optimal cooling performance for the upcoming season.
# HVAC Install - Complete System
Completed full residential HVAC system installation including outdoor condensing unit and indoor control components. Installed new AC condenser on gravel pad with proper electrical disconnects, conduit routing, and code-compliant wiring connections. Mounted and wired control board with integrated diagnostics and safety features. Performed system startup procedures and verified proper operation of all components. Addressed airflow imbalance concerns between bedrooms by evaluating ductwork distribution and system controls to optimize heating performance throughout the home.
Completed scheduled cooling system maintenance on Lennox Elite Series system. Performed comprehensive inspection of outdoor condenser unit and indoor furnace components, verified proper operation of all equipment, documented system condition with photographs, and confirmed unit is functioning within normal parameters for continued reliable cooling performance.
Completed second appointment to troubleshoot HVAC system with problematic dampers previously identified during initial diagnostic visit. Performed comprehensive A/C tune-up on outdoor condensing unit, including inspection of cylindrical coil assembly which showed weathering, mineral deposits, and debris accumulation between fins. Documented unit condition with exterior coil displaying surface discoloration and foam insulation material along refrigerant line connections, with system mounted on rubber pad in gravel bed adjacent to property fence line.
Completed comprehensive preventative maintenance on both air conditioning and furnace systems. Performed full system inspection of HVAC unit including blower motor assembly, electrical connections, control board, and all safety components. Inspected condensate drain lines, refrigerant lines, and ductwork connections. Verified proper operation of all mechanical and electrical components, checked air filter, and ensured system is operating within manufacturer specifications for optimal performance and efficiency.
Completed comprehensive HVAC maintenance service including air conditioning system inspection and furnace evaluation. Replaced Skuttle humidifier evaporator pad (part number A04-1725-052) as requested by customer. Inspected control board, wiring connections, and relay components within furnace unit, verified proper humidifier operation with copper supply line connections, and documented equipment condition with photos for service records.
Completed initial heating and cooling maintenance visit on 17-year-old HVAC system. Performed comprehensive inspection of furnace burner assembly, noting oxidation present on burner tubes and heat exchanger components consistent with system age. Conducted flue gas analysis using combustion analyzer, measuring stack temperature at 103.4°F, oxygen level at 8.9%, carbon monoxide at 6 ppm, and combustion efficiency at 93.4%. System operating within acceptable parameters. Renewed maintenance agreement during visit.
Completed comprehensive estimate for replacement of existing 10-ton split system HVAC unit with 14 SEER equipment. Inspected current York condenser unit and interior air handler, documenting significant deterioration of internal insulation material and overall system wear. Provided detailed assessment and replacement recommendations for complete system upgrade.
Completed comprehensive AC tune-up on 20-year-old outdoor cooling unit. Performed standard maintenance protocol including inspection of ductwork and flexible connections, verified system operation, and documented equipment condition with interior duct camera inspection showing corrugated transition ductwork and ventilation pathways. Unit operational and ready for cooling season.
Completed preventative maintenance tune-up on 3-year-old Lennox air conditioning system. Performed comprehensive inspection of outdoor condensing unit, verified proper electrical connections at capacitor and contactor, checked refrigerant levels, and confirmed system operational efficiency. All components found to be functioning within normal parameters.